Evidence map›Paper›PMID 26110503›Full record

ArticleToxins2015

Application of Microwave Irradiation and Heat to Improve Gliadin Detection and Ricin ELISA Throughput with Food Samples.

Eric A E Garber, Joseph Thole

Open access · goldAbstract read
In one paragraph

Article in Toxins, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 11 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Eric A E GarberOffice of Regulatory Science, Center for Food Safety and Applied Nutrition, Food and Drug Administration, College Park, MD 20740, USA. eric.garber@fda.hhs.gov.
Joseph TholeJoint Institute for Food Safety and Applied Nutrition (JIFSAN), University of Maryland, College Park, MD 20742, USA. jthole@terpmail.umd.edu.
Center for Food Safety and Applied Nutrition · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The utility of microwave irradiation to accelerate the onset of equilibrium and improve ELISA performance was examined using ELISAs for the detection of the plant toxin ricin and gliadin. The ricin ELISA normally requires several one hour incubations at 37 °C, a total assay time of approximately five hours, and employs a complex buffer containing PBS, Tween-20®, and non-fat milk. Different energy levels and pulse designs were compared to the use of abbreviated incubation times at 37 °C for the detection of ricin in food. The use of microwave irradiation had no significant advantage over the application of heat using an oven incubator and performed worse with some foods. In contrast, a gliadin ELISA that relied on 30 min incubation steps at room temperature and a salt-based buffer performed better upon irradiation but also displayed improvement upon incubating the microtiter plate at 37 °C. Whether microwave irradiation was advantageous compared to incubation in an oven was inconclusive. However, by abbreviating the incubation time of the ricin ELISA, it was possible to cut the assay time to less than 2 hours and still display LOD values < 10 ppb and recoveries of 78%-98%.

Indexed as

AnimalsBreadCarbonated BeveragesCitrus sinensisEnzyme-Linked Immunosorbent AssayFood ContaminationFruit and Vegetable JuicesGliadinHot TemperatureMicrowavesMilkRicinToxins, BiologicalGliadinRicinToxins, BiologicalELISAglutenmicrowavericin

Identifiers

PMID26110503
PMCPMC4488694
OpenAlexW1495800936

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.