Evidence map›Paper›PMID 26107177›Full record

ArticlePloS one2015

Tantalum Nitride-Decorated Titanium with Enhanced Resistance to Microbiologically Induced Corrosion and Mechanical Property for Dental Application.

Yifei Zhang, Yunfei Zheng, Yongliang Li, Lixin Wang, Yanjie Bai, Qiang Zhao, Xiaoling Xiong, Yan Cheng, Zhihui Tang, Yi Deng and 1 more

Open access · goldAbstract readEvaluation Study
In one paragraph

Article in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed, 1 pooled it
5.3field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 1 synthesis or guideline pooled it, 75 citations in OpenAlex.

  1. Microbial Biofilm Decontamination on Dental Implant Surfaces: A Mini Review.Frontiers in cellular and infection microbiology · 2021
    Pooled it
  2. Article
  3. Article
  4. Review
  5. Review
  6. Article
  7. Review
  8. Review
  9. Applications of Gold and Silver Nanoparticles in Theranostics.Applied biochemistry and biotechnology · 2022
    Review
  10. Article
  11. Article
  12. Review
  13. Review
  14. Review
  15. Article
  16. Article
  17. [In vivo study of 3D printed porous tantalum implant on osseointegration].Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology · 2018
    Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 3 institutions in 1 country.

Yifei ZhangDepartment of Oral and Maxillofacial Surgery, Laboratory of Interdisciplinary Studies, School and Hospital of Stomatology, Peking University Beijing 100081, China; 2nd Dental Center, School and Hospital of Stomatology, Peking University Beijing 100081, China.
Yunfei ZhengDepartment of Oral and Maxillofacial Surgery, Laboratory of Interdisciplinary Studies, School and Hospital of Stomatology, Peking University Beijing 100081, China; 2nd Dental Center, School and Hospital of Stomatology, Peking University Beijing 100081, China.
Yongliang LiDepartment of Oral and Maxillofacial Surgery, Laboratory of Interdisciplinary Studies, School and Hospital of Stomatology, Peking University Beijing 100081, China; 2nd Dental Center, School and Hospital of Stomatology, Peking University Beijing 100081, China.
Lixin WangDepartment of Stomatology, Beijing Shijitan Hospital, Capital Medical University Beijing 100038, China.
Yanjie BaiDepartment of Stomatology, Aviation General Hospital of China Medical University and Beijing Institute of Translational Medicine, Chinese Academy of Science, Beijing 100012, China.
Qiang ZhaoDepartment of Stomatology, Aviation General Hospital of China Medical University and Beijing Institute of Translational Medicine, Chinese Academy of Science, Beijing 100012, China.
Xiaoling XiongDepartment of Oral and Maxillofacial Surgery, Laboratory of Interdisciplinary Studies, School and Hospital of Stomatology, Peking University Beijing 100081, China.
Yan ChengCenter for Biomedical Materials and Tissue Engineering, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871, China.
Zhihui Tang2nd Dental Center, School and Hospital of Stomatology, Peking University Beijing 100081, China.
Yi DengCenter for Biomedical Materials and Tissue Engineering, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871, China.
Shicheng WeiDepartment of Oral and Maxillofacial Surgery, Laboratory of Interdisciplinary Studies, School and Hospital of Stomatology, Peking University Beijing 100081, China; 2nd Dental Center, School and Hospital of Stomatology, Peking University Beijing 100081, China; Center for Biomedical Materials and Tissue Engineering, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871, China.
Peking University · CNAviation General Hospital · CNCapital Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Microbiologically induced corrosion (MIC) of metallic devices/implants in the oral region is one major cause of implant failure and metal allergy in patients. Therefore, it is crucial to develop practical approaches which can effectively prevent MIC for broad clinical applications of these materials. In the present work, tantalum nitride (TaN)-decorated titanium with promoted bio-corrosion and mechanical property was firstly developed via depositing TaN layer onto pure Ti using magnetron sputtering. The microstructure and chemical constituent of TaN coatings were characterized, and were found to consist of a hard fcc-TaN outer layer. Besides, the addition of TaN coatings greatly increased the hardness and modulus of pristine Ti from 2.54 ± 0.20 to 29.88 ± 2.59 GPa, and from 107.19 ± 6.98 to 295.46 ± 19.36 GPa, respectively. Potentiodynamic polarization and electrochemical impedance spectroscopy studies indicated that TaN coating exhibited higher MIC resistance in comparison to bare Ti and TiN-coated coating in two bacteria-containing artificial saliva solutions. Moreover, the biofilm experiment showed that the TaN-decorated Ti sample possessed good antibacterial performance. The SEM and XPS results after biofilm removal demonstrated that TaN film remained its integrity and stability, while TiN layer detached from Ti surface in the bio-corrosion tests, demonstrating the anti-MIC behavior and the strong binding property of TaN coating to Ti substrate. Considering all these results, TaN-decorated Ti material exhibits the optimal comprehensive performance and holds great potential as implant material for dental applications.

Indexed as

Actinomyces viscosusBiofilmsCoated Materials, BiocompatibleCorrosionDental ImplantsDental MaterialsDielectric SpectroscopyElastic ModulusHardnessMaterials TestingMicroscopy, Electron, ScanningNitrogen CompoundsPhotoelectron SpectroscopyPorphyromonas gingivalisStreptococcus mutansStress, MechanicalCoated Materials, BiocompatibleDental ImplantsDental MaterialsNitrogen CompoundsTantalumTitanium

Identifiers

PMID26107177
PMCPMC4479376
OpenAlexW2219603464

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.