Evidence map›Paper›PMID 26090829›Full record

ArticleJournal of neurosurgery2015

High-fidelity virtual stenting: modeling of flow diverter deployment for hemodynamic characterization of complex intracranial aneurysms.

Jianping Xiang, Robert J Damiano, Ning Lin, Kenneth V Snyder, Adnan H Siddiqui, Elad I Levy, Hui Meng

Open access · bronzeAbstract read
In one paragraph

Article in Journal of neurosurgery, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
5.8field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed, 68 citations in OpenAlex.

  1. Article
  2. Software-based simulation for pipeline vantage flow diverter preprocedural assessment: Method and validation study.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  3. Hemodynamics in Cerebral Aneurysms and Parent Arteries With Incompletely Expanded Flow Diverter Stents.International journal for numerical methods in biomedical engineering · 2025
    Article
  4. Article
  5. Article
  6. De novo aneurysm formation after flow diverter stent placement.Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology · 2023
    Article
  7. Predicting flow diverter sizing using the AneuGuideJournal of neurointerventional surgery · 2023
    Article
  8. Article
  9. Article
  10. Semi-automated cerebral aneurysm segmentation and geometric analysis for WEB sizing utilizing a cloud-based computational platform.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2021
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Jianping XiangToshiba Stroke and Vascular Research Center.
Robert J DamianoToshiba Stroke and Vascular Research Center.
Ning LinDepartment of Neurosurgery.
Kenneth V SnyderToshiba Stroke and Vascular Research Center.
Adnan H SiddiquiToshiba Stroke and Vascular Research Center.
Elad I LevyToshiba Stroke and Vascular Research Center.
Hui MengToshiba Stroke and Vascular Research Center.
Toshiba (Japan) · JPUniversity at Buffalo, State University of New York · USNewYork–Presbyterian Hospital · US

Funding

University of Buffalo Clinical and Translational Science Institute - Supplement SchulyerUL1TR001412 · NCATS · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI MURPHY, TIMOTHY F · 2015 to 2024
$33.8M
Micro-Radiographic Imager for Neuroovascular InterventionsR01EB002873 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2003 to 2015
$5.6M
Virtual Intervention of Intracranial AneurysmsR01NS091075 · NINDS · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI MENG, HUI · 2015 to 2019
$1.7M
NCATS NIH HHS UL1 TR001412NIBIB NIH HHS 5R01EB002873NINDS NIH HHS R01 NS091075NINDS NIH HHS R01NS091075-01
6 · The paper itself

Abstract

objectFlow diversion via Pipeline Embolization Device (PED) represents the most recent advancement in endovascular therapy of intracranial aneurysms. This exploratory study aims at a proof of concept for an advanced device-modeling tool in conjunction with computational fluid dynamics (CFD) to evaluate flow modification effects by PED in actual, treated cases.

methodsThe authors performed computational modeling of 3 PED-treated complex aneurysm cases. The patient in Case 1 had a fusiform vertebral aneurysm treated with a single PED. In Case 2 the patient had a giant internal carotid artery (ICA) aneurysm treated with 2 PEDs. Case 3 consisted of tandem ICA aneurysms (III-a and III-b) treated by a single PED. The authors' recently developed high-fidelity virtual stenting (HiFiVS) technique was used to recapitulate the clinical deployment process of PEDs in silico for these 3 cases. Pretreatment and posttreatment aneurysmal hemodynamics studies performed using CFD simulation were analyzed. Changes in aneurysmal flow velocity, inflow rate, wall shear stress (WSS), and turnover time were calculated and compared with the clinical outcome.

resultsIn Case 1 (occluded within the first 3 months), the aneurysm had the most drastic flow reduction after PED placement; the aneurysmal average velocity, inflow rate, and average WSS were decreased by 76.3%, 82.5%, and 74.0%, respectively, whereas the turnover time was increased to 572.1% of its pretreatment value. In Case 2 (occluded at 6 months), aneurysmal average velocity, inflow rate, and average WSS were decreased by 39.4%, 38.6%, and 59.1%, respectively, and turnover time increased to 163.0%. In Case 3, Aneurysm III-a (occluded at 6 months) had a decrease by 38.0%, 28.4%, and 50.9% in average velocity, inflow rate, and average WSS, respectively, and turnover time increased to 139.6%, which was quite similar to Aneurysm II. Surprisingly, the adjacent Aneurysm III-b had more substantial flow reduction (a decrease by 77.7%, 53.0%, and 84.4% in average velocity, inflow rate, and average WSS, respectively, and an increase to 213.0% in turnover time) than Aneurysm III-a, which qualitatively agreed with angiographic observation at 3-month follow-up. However, Aneurysm III-b remained patent at both 6 months and 9 months. A closer examination of the vascular anatomy in Case 3 revealed blood draining to the ophthalmic artery off Aneurysm III-b, which may have prevented its complete thrombosis.

conclusionsThis proof-of-concept study demonstrates that HiFiVS modeling of flow diverter deployment enables detailed characterization of hemodynamic alteration by PED placement. Posttreatment aneurysmal flow reduction may be correlated with aneurysm occlusion outcome. However, predicting aneurysm treatment outcome by flow diverters also requires consideration of other factors, including vascular anatomy.

Indexed as

Endovascular ProceduresHemodynamicsModels, CardiovascularStentsAgedEmbolization, TherapeuticFemaleHumansIntracranial AneurysmMaleMiddle AgedCFD = computational fluid dynamicscomputational fluid dynamicsFD = flow diverterflow diverterHiFiVS = high-fidelity virtual stentinghigh-fidelity virtual stentingICA = internal carotid arteryintracranial aneurysmOphA = ophthalmic arteryPED = Pipeline Embolization DevicePICA = posterior inferior cerebellar arteryPipeline Embolization Devicestent modelingvascular disordersVA = vertebral arteryWSS = wall shear stress

Identifiers

PMID26090829
PMCPMC4792250
OpenAlexW1486922965

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked