Evidence map›Paper›PMID 26086817›Full record

ArticlePloS one2015

Telemetric Blood Pressure Assessment in Angiotensin II-Infused ApoE-/- Mice: 28 Day Natural History and Comparison to Tail-Cuff Measurements.

Christopher M Haggerty, Andrea C Mattingly, Ming C Gong, Wen Su, Alan Daugherty, Brandon K Fornwalt

Open access · goldAbstract readComparative Study
In one paragraph

Article in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 33 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Rodent Thermoregulation: Considerations for Tail-Cuff Blood Pressure Measurements.Journal of the American Association for Laboratory Animal Science : JAALAS · 2022
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Christopher M HaggertySaha Cardiovascular Research Center, University of Kentucky, Lexington, Kentucky, United States of America.
Andrea C MattinglySaha Cardiovascular Research Center, University of Kentucky, Lexington, Kentucky, United States of America.
Ming C GongDepartment of Physiology, University of Kentucky, Lexington, Kentucky, United States of America.
Wen SuSaha Cardiovascular Research Center, University of Kentucky, Lexington, Kentucky, United States of America.
Alan DaughertySaha Cardiovascular Research Center, University of Kentucky, Lexington, Kentucky, United States of America.
Brandon K FornwaltSaha Cardiovascular Research Center, University of Kentucky, Lexington, Kentucky, United States of America; Department of Physiology, University of Kentucky, Lexington, Kentucky, United States of America; Department of Biomedical Engineering, University of Kentucky, Lexington, Kentucky, United States of America; Department of Pediatrics, University of Kentucky, Lexington, Kentucky, United States of America.
University of Kentucky · US

Funding

The role of IKKß in linking obesity to adipose tissue inflammation and adipogeneP20GM103527 · NIGMS · UNIVERSITY OF KENTUCKY · PI REN, HONGMEI · 2012 to 2017
$13.7M
Kentucky Center for Clinical and Translational ScienceUL1TR000117 · NCATS · UNIVERSITY OF KENTUCKY · PI KERN, PHILIP A · 2012 to 2015
$13.3M
Kentucky Center for Clinical and Translational ScienceKL2TR000116 · NCATS · UNIVERSITY OF KENTUCKY · PI KERN, PHILIP A · 2012 to 2015
$1.9M
Aortic Wall Distensibility in the Growth and Rupture of Abdominal Aortic AneurysmF32HL123215 · NHLBI · UNIVERSITY OF KENTUCKY · PI HAGGERTY, CHRISTOPHER M · 2014 to 2014
$52k
NCATS NIH HHS KL2 TR000116NCATS NIH HHS UL1 TR000117NCATS NIH HHS UL1TR000117NHLBI NIH HHS F32 HL123215NIGMS NIH HHS P20 GM103527
6 · The paper itself

Abstract

Abdominal aortic aneurysm (AAA) is a disease of the aortic wall, which can progress to catastrophic rupture. Assessment of mechanical characteristics of AAA, such as aortic distensibility, may provide important insights to help identify at-risk patients and understand disease progression. While the majority of studies on this topic have focused on retrospective patient data, recent studies have used mouse models of AAA to prospectively evaluate the evolution of aortic mechanics. Quantification of aortic distensibility requires accurate measurement of arterial blood pressure, particularly pulse pressure, which is challenging to perform accurately in murine models. We hypothesized that volume/pressure tail-cuff measurements of arterial pulse pressure in anesthetized mice would have sufficient accuracy to enable calculations of aortic distensibility with minimal error. Telemetry devices and osmotic mini-pumps filled with saline or angiotensin-II were surgically implanted in male apolipoprotein-E deficient (ApoE(-/-)) mice. Blood pressure in the aortic arch was measured continuously via telemetry. In addition, simultaneous blood pressure measurements with a volume/pressure tail-cuff system were performed under anesthesia at specific intervals to assess agreement between techniques. Compared to controls, mice infused with angiotensin-II had an overall statistically significant increase in systolic pressure, with no overall difference in pulse pressure; however, pulse pressure did increase significantly with time. Systolic measurements agreed well between telemetry and tail-cuff (coefficient of variation = 10%), but agreement of pulse pressure was weak (20%). In fact, group-averaged pulse pressure from telemetry was a better predictor of a subject's pulse pressure on a given day than a simultaneous tail-cuff measurement. Furthermore, these approximations introduced acceptable errors (15.1 ± 12.8%) into the calculation of aortic distensibility. Contrary to our hypothesis, we conclude that tail-cuff measures of arterial pulse pressure have limited accuracy. Future studies of aneurysm mechanics using the ApoE(-/-)/angiotensin-II model would be better in assuming pulse pressure profiles consistent with our telemetry findings instead of attempting to measure pulse pressure in individual mice.

Indexed as

Blood PressureAngiotensin IIAnimalsAortaAortic Aneurysm, AbdominalApolipoproteins EBlood Pressure DeterminationGene DeletionMaleMiceMice, Inbred C57BLTelemetryAngiotensin IIApolipoproteins E

Identifiers

PMID26086817
PMCPMC4472759
OpenAlexW577916619

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.