Evidence map›Paper›PMID 26085565›Full record

ArticleJournal of diabetes science and technology2015

Preclinical Evaluation of Poly(HEMA-co-acrylamide) Hydrogels Encapsulating Glucose Oxidase and Palladium Benzoporphyrin as Fully Implantable Glucose Sensors.

Rachel M Unruh, Jason R Roberts, Scott P Nichols, Soya Gamsey, Natalie A Wisniewski, Michael J McShane

Abstract readEvaluation Study
In one paragraph

Article in Journal of diabetes science and technology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Review
  11. Article
  12. Review
  13. Article
  14. Article
  15. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Rachel M UnruhDepartment of Biomedical Engineering, Texas A&M University, College Station, TX, USA.
Jason R RobertsDepartment of Biomedical Engineering, Texas A&M University, College Station, TX, USA.
Scott P NicholsPROFUSA, Inc, San Francisco, CA, USA.
Soya GamseyPROFUSA, Inc, San Francisco, CA, USA.
Natalie A WisniewskiPROFUSA, Inc, San Francisco, CA, USA.
Michael J McShaneDepartment of Biomedical Engineering, Texas A&M University, College Station, TX, USA Department of Materials Science and Engineering, Texas A&M University, College Station, TX, USA mcshane@tamu.edu.

Funding

Implantable multi-analyte sensors for the continuous monitoring of body chemistriR01EB016414 · NIBIB · PROFUSA, INC. · PI MCSHANE, MIKE, WISNIEWSKI, NATALIE ANN · 2012 to 2015
$4.9M
Long-term Luminescence-based Glucose MonitoringR43DK093139 · NIDDK · PROFUSA, INC. · PI WISNIEWSKI, NATALIE ANN · 2011 to 2013
$1.1M
NIBIB NIH HHS 1R01EB016414NIBIB NIH HHS R01 EB016414NIDDK NIH HHS 1R43DK093139NIDDK NIH HHS R43 DK093139
6 · The paper itself

Abstract

backgroundContinuous glucose monitors (CGMs) require percutaneous wire probes to monitor glucose. Sensors based on luminescent hydrogels are being explored as fully implantable alternatives to traditional CGMs. Our previous work investigated hydrogel matrices functionalized with enzymes and oxygen-quenched phosphors, demonstrating sensitivity to glucose, range of response, and biofouling strongly depend on the matrix material. Here, we further investigate the effect of matrix composition on overall performance in vitro and in vivo.

methodsSensors based on three hydrogels, a poly(2-hydroxyethyl methacrylate) (pHEMA) homopolymer and 2 poly(2-hydroxyethyl methacrylate-co-acrylamide) (pHEMA-co-AAm) copolymers, were compared. These were used to entrap glucose oxidase (GOx), catalase, and an oxygen-sensitive benzoporphyrin phosphor. All sensor formulations were evaluated for glucose response and stability at physiological temperatures. Selected sensors were then evaluated as implanted sensors in a porcine model challenged with glucose and insulin. The animal protocol used in this study was approved by an IACUC committee at Texas A&M University.

resultsPHEMA-co-AAm copolymer hydrogels (75:25 HEMA:AAm) yielded the most even GOx and dye dispersion throughout the hydrogel matrix and best preserved GOx apparent activity. In response to in vitro glucose challenges, this formulation exhibited a dynamic range of 12-167 mg/dL, a sensitivity of 1.44 ± 0.46 µs/(mg/dL), and tracked closely with reference capillary blood glucose values in vivo.

conclusionsThe hydrogel-based sensors exhibited excellent sensitivity and sufficiently rapid response to the glucose levels achieved in vivo, proving feasibility of these materials for use in real-time glucose tracking. Extending the dynamic range and assessing long-term effects in vivo are ongoing efforts.

Indexed as

Glucose OxidaseHydrogelsPalladiumAnimalsBiosensing TechniquesBlood GlucoseFemaleInsulin Infusion SystemsSwineSwine, MiniatureBlood GlucoseGlucose OxidaseHydrogelsPalladiumbiomaterialsbiosensingenzymeshydrogelimplantluminescence

Identifiers

PMID26085565
PMCPMC4667330

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.