Evidence map›Paper›PMID 26077987›Full record

ArticleAnnals of biomedical engineering2015

Ultrasound Elastography for Estimation of Regional Strain of Multilayered Hydrogels and Tissue-Engineered Cartilage.

Chen-Yuan Chung, Joseph Heebner, Harihara Baskaran, Jean F Welter, Joseph M Mansour

Abstract read
In one paragraph

Article in Annals of biomedical engineering, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Apparatus and Method for Rapid Detection of Acoustic Anisotropy in Cartilage.Journal of medical and biological engineering · 2020
    Article
  5. Article
  6. Review
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Chen-Yuan ChungDepartment of Mechanical and Aerospace Engineering, Case Western Reserve University, 2123 Martin Luther King Jr. Drive, Glennan Building Room 616A, Cleveland, OH, 44106, USA.
Joseph HeebnerDepartment of Mechanical and Aerospace Engineering, Case Western Reserve University, 2123 Martin Luther King Jr. Drive, Glennan Building Room 616A, Cleveland, OH, 44106, USA.
Harihara BaskaranDepartment of Chemical and Biomolecular Engineering, Case Western Reserve University, Cleveland, OH, USA.
Jean F WelterDepartment of Biology (Skeletal Research Center), Case Western Reserve University, Cleveland, OH, USA.
Joseph M MansourDepartment of Mechanical and Aerospace Engineering, Case Western Reserve University, 2123 Martin Luther King Jr. Drive, Glennan Building Room 616A, Cleveland, OH, 44106, USA. jmm12@case.edu.

Funding

Total Joint ResurfacingP01AR053622 · NIAMS · CASE WESTERN RESERVE UNIVERSITY · PI MANSOUR, JOSEPH M · 2008 to 2012
$6.0M
Engineering cartilage: an approach to joint repair.R01AR050208 · NIAMS · CASE WESTERN RESERVE UNIVERSITY · PI WELTER, JEAN F · 2005 to 2009
$1.6M
CWRU Center for Multimodal Evaluation of Engineered CartilageR01EB020367 · NIBIB · CASE WESTERN RESERVE UNIVERSITY · PI CAPLAN, ARNOLD IRWIN · 2014 to 2015
$807k
NIAMS NIH HHS AR050208NIAMS NIH HHS P01 AR053622NIAMS NIH HHS R01 AR050208NIBIB NIH HHS R01 EB020367NIBIB NIH HHS R01 EB20367-01
6 · The paper itself

Abstract

Tissue-engineered (TE) cartilage constructs tend to develop inhomogeneously, thus, to predict the mechanical performance of the tissue, conventional biomechanical testing, which yields average material properties, is of limited value. Rather, techniques for evaluating regional and depth-dependent properties of TE cartilage, preferably non-destructively, are required. The purpose of this study was to build upon our previous results and to investigate the feasibility of using ultrasound elastography to non-destructively assess the depth-dependent biomechanical characteristics of TE cartilage while in a sterile bioreactor. As a proof-of-concept, and to standardize an assessment protocol, a well-characterized three-layered hydrogel construct was used as a surrogate for TE cartilage, and was studied under controlled incremental compressions. The strain field of the construct predicted by elastography was then validated by comparison with a poroelastic finite-element analysis (FEA). On average, the differences between the strains predicted by elastography and the FEA were within 10%. Subsequently engineered cartilage tissue was evaluated in the same test fixture. Results from these examinations showed internal regions where the local strain was 1-2 orders of magnitude greater than that near the surface. These studies document the feasibility of using ultrasound to evaluate the mechanical behaviors of maturing TE constructs in a sterile environment.

Indexed as

BioreactorsCartilage, ArticularCells, CulturedElasticity Imaging TechniquesFinite Element AnalysisHumansHydrogelsMesenchymal Stem CellsReproducibility of ResultsStress, MechanicalTissue EngineeringHydrogelsAcoustic methodsBioreactorDepth-dependent deformationMechanical propertiesMultimodal evaluation

Identifiers

PMID26077987
PMCPMC4626304

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.