Evidence map›Paper›PMID 26075842›Full record

ArticleThe journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians2016

Placenta-on-a-chip: a novel platform to study the biology of the human placenta.

Ji Soo Lee, Roberto Romero, Yu Mi Han, Hee Chan Kim, Chong Jai Kim, Joon-Seok Hong, Dongeun Huh

Abstract read
In one paragraph

Article in The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 135 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
135citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

135 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Review
  5. Review
  6. Article
  7. Review
  8. Review
  9. Review
  10. Review
  11. Modelling mammalian implantationAnimal reproduction · 2026
    Review
  12. Exosomal Delivery of Interleukin-10 Reduces Infection-Associated Inflammation in a 3D-Printed Model of a Humanized Feto-Maternal Interface.FASEB journal : official publication of the Federation of American Societies for Experimental Biology · 2025
    Article
  13. Review
  14. Review
  15. Review
  16. NAM journal · 2025
    Review
  17. Review
  18. Article
  19. Article
  20. Article

75 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ji Soo Leea Interdisciplinary Program of Bioengineering, Seoul National University Graduate School , Seoul , Republic of Korea .
Roberto Romerob Perinatology Research Branch, Program for Perinatal Research and Obstetrics, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development , NIH, Bethesda, MD and Detroit, MI , USA .
Yu Mi Hanf Department of Obstetrics and Gynecology , Seoul National University Bundang Hospital , Gyeonggi-do , Republic of Korea .
Hee Chan Kimg Institute of Medical and Biological Engineering, Medical Research Center, Seoul National University , Seoul , Republic of Korea .
Chong Jai Kimj Department of Pathology , Asan Medical Center, University of Ulsan College of Medicine , Seoul , Republic of Korea , and.
Joon-Seok Hongf Department of Obstetrics and Gynecology , Seoul National University Bundang Hospital , Gyeonggi-do , Republic of Korea .
Dongeun Huhk Department of Bioengineering , University of Pennsylvania , Philadelphia , PA , USA.

Funding

Translational Research Support CoreP30ES013508 · NIEHS · UNIVERSITY OF PENNSYLVANIA · PI Rebecca A Simmons · 2006 to 2026
$35.3M
Probing the physics of chronic lung disease using microphysiological biomimicryDP2HL127720 · NHLBI · UNIVERSITY OF PENNSYLVANIA · PI HUH, DONGEUN · 2014 to 2014
$2.4M
Intramural NIH HHSNCCDPHP CDC HHS 1DP2HL127720-01NHLBI NIH HHS DP2 HL127720NICHD NIH HHS HHSN275201300006CNICHD NIH HHS N01 HD023342NIEHS NIH HHS P30 ES013508PHS HHS HSN275201300006C
6 · The paper itself

Abstract

objectiveStudying the biology of the human placenta represents a major experimental challenge. Although conventional cell culture techniques have been used to study different types of placenta-derived cells, current in vitro models have limitations in recapitulating organ-specific structure and key physiological functions of the placenta. Here we demonstrate that it is possible to leverage microfluidic and microfabrication technologies to develop a microengineered biomimetic model that replicates the architecture and function of the placenta. MATERIALS AND

methodsA "Placenta-on-a-Chip" microdevice was created by using a set of soft elastomer-based microfabrication techniques known as soft lithography. This microsystem consisted of two polydimethylsiloxane (PDMS) microfluidic channels separated by a thin extracellular matrix (ECM) membrane. To reproduce the placental barrier in this model, human trophoblasts (JEG-3) and human umbilical vein endothelial cells (HUVECs) were seeded onto the opposite sides of the ECM membrane and cultured under dynamic flow conditions to form confluent epithelial and endothelial layers in close apposition. We tested the physiological function of the microengineered placental barrier by measuring glucose transport across the trophoblast-endothelial interface over time. The permeability of the barrier study was analyzed and compared to that obtained from acellular devices and additional control groups that contained epithelial or endothelial layers alone.

resultsOur microfluidic cell culture system provided a tightly controlled fluidic environment conducive to the proliferation and maintenance of JEG-3 trophoblasts and HUVECs on the ECM scaffold. Prolonged culture in this model produced confluent cellular monolayers on the intervening membrane that together formed the placental barrier. This in vivo-like microarchitecture was also critical for creating a physiologically relevant effective barrier to glucose transport. Quantitative investigation of barrier function was conducted by calculating permeability coefficients and metabolic rates in varying conditions of barrier structure. The rates of glucose transport and metabolism were consistent with previously reported in vivo observations.

conclusionThe "Placenta-on-a-Chip" microdevice described herein provides new opportunities to simulate and analyze critical physiological responses of the placental barrier. This system may be used to address the major limitations of existing placenta model systems and serve to enable research platforms for reproductive biology and medicine.

Indexed as

Cell Culture TechniquesLab-On-A-Chip DevicesBioengineeringBiological TransportCells, CulturedCoculture TechniquesFemaleGlucoseHumansHuman Umbilical Vein Endothelial CellsPlacentaPregnancyTrophoblastsGlucoseGlucose transfermicrofluidicsorgan-on-a-chipplacenta in vitro modelplacental barrier

Identifiers

PMID26075842
PMCPMC5625348

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.