SynthesisThe Cochrane database of systematic reviews2015
Devices and dressings to secure peripheral venous catheters to prevent complications.
Synthesis in The Cochrane database of systematic reviews, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 3 registered trials, which are not on this map. Cited by 29 papers, 5 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Transfer of Technological Innovations to Nursing Practice: A Contribution to the Prevention of Infections
Innovative Device for Intravenous Administration
Effects of Chlorhexidine Solutions With Different Concentrations in Preventing Peripheral Venous Catheter-Associated Infections
Who cites it
29 citing papers in PubMed, 5 syntheses or guidelines pooled it, 93 citations in OpenAlex.
- Effectiveness and Safety of Different Dressing and Securement Methods for Peripheral Intravenous Catheters: A Systematic Review and Meta-Analysis.International wound journal · 2026Pooled it
- Dressings and securement devices to prevent complications for peripheral arterial catheters.The Cochrane database of systematic reviews · 2024Pooled it
- Vascular access specialist teams for device insertion and prevention of failure.The Cochrane database of systematic reviews · 2018Pooled it
- Closure Devices for Iatrogenic Thoraco-Cervical Vascular Injuries.Cardiovascular and interventional radiology · 2017Pooled it
- Quality Improvement Interventions for Peripheral Intravenous Catheter Nursing Practices: A Systematic Review.Journal of nursing care qualityPooled it
- Comparing the Effects of Sesame Oil vs. Nitroglycerin Ointment on the Incidence of Chemotherapy-Induced Phlebitis: A Single Blind Clinical Trial.Asian Pacific journal of cancer prevention : APJCP · 2023Trial
- Integrated versus nonintegrated peripheral intravenous catheter in hospitalized adults (OPTIMUM): A randomized controlled trial.Journal of hospital medicine · 2023Trial
- Trial
- Trial
- Navigating the veins: A comprehensive review of vasoactive agent infusionWorld journal of critical care medicine · 2026Review
- Detection of peripheral infusion-related infiltration and extravasation in neonates: a scoping review.Pediatric research · 2026Article
- Implementation of an Infection Prevention Care Bundle for Peripheral Intravenous Catheters (PIVCs): A Quality Improvement Study to Enhance PIVC Quality and Reduce Complications.Nursing reports (Pavia, Italy) · 2025Article
- Association between peripheral venous catheter failure and care complexity factors in emergency department: a cross-sectional study.BMJ open · 2024Article
- Article
- Observational
- Impact of terminal tip location of midline catheters on catheter-related complications and indwelling duration in elderly patients.Nursing open · 2023Article
- Short Peripheral Venous Catheters Contamination and the Dangers of Bloodstream Infection in Portugal: An Analytic Study.Microorganisms · 2023Article
- Pediatric robotic surgery: issues in management-expert consensus from the Italian Society of Pediatric and Neonatal Anesthesia and Intensive Care (SARNePI) and the Italian Society of Pediatric Surgery (SICP).Surgical endoscopy · 2022Article
- Article
- The Efficacy, Safety, and Convenience of a New Device for Flushing Intravenous Catheters (Baro Flush™): A Prospective Study.Medicina (Kaunas, Lithuania) · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundA peripheral venous catheter (PVC) is typically used for short-term delivery of intravascular fluids and medications. It is an essential element of modern medicine and the most frequent invasive procedure performed in hospitals. However, PVCs often fail before intravenous treatment is completed: this can occur because the device is not adequately attached to the skin, allowing the PVC to fall out, leading to complications such as phlebitis (irritation or inflammation to the vein wall), infiltration (fluid leaking into surrounding tissues) or occlusion (blockage). An inadequately secured PVC also increases the risk of catheter-related bloodstream infection (CRBSI), as the pistoning action (moving back and forth in the vein) of the catheter can allow migration of organisms along the catheter and into the bloodstream. Despite the many dressings and securement devices available, the impact of different securement techniques for increasing PVC dwell time is still unclear; there is a need to provide guidance for clinicians by reviewing current studies systematically.
objectivesTo assess the effects of PVC dressings and securement devices on the incidence of PVC failure. SEARCH
methodsWe searched the following electronic databases to identify reports of relevant randomised controlled trials (RCTs): the Cochrane Wounds Group Register (searched 08 April 2015): The Cochrane Central Register of Controlled Trials (CENTRAL; 2015, Issue 3), Ovid MEDLINE (1946 to March 7 2015); Ovid MEDLINE (In-Process & Other Non-Indexed Citations, March 7 2015); Ovid EMBASE (1974 to March 7 2015); and EBSCO CINAHL (1982 to March 8 2015). SELECTION CRITERIA: RCTs or cluster RCTs comparing different dressings or securement devices for the stabilisation of PVCs. Cross-over trials were ineligible for inclusion, unless data for the first treatment period could be obtained. DATA COLLECTION AND ANALYSIS: Two review authors independently selected studies, assessed trial quality and extracted data. We contacted study authors for missing information. We used standard methodological procedures expected by Cochrane. MAIN
resultsWe included six RCTs (1539 participants) in this review. Trial sizes ranged from 50 to 703 participants. These six trials made four comparisons, namely: transparent dressings versus gauze; bordered transparent dressings versus a securement device; bordered transparent dressings versus tape; and transparent dressing versus sticking plaster. There is very low quality evidence of fewer catheter dislodgements or accidental removals with transparent dressings compared with gauze (two studies, 278 participants, RR 0.40; 95% CI 0.17 to 0.92, P = 0.03%). The relative effects of transparent dressings and gauze on phlebitis (RR 0.89; 95% CI 0.47 to 1.68) and infiltration (RR 0.80; 95% CI 0.48 to 1.33) are unclear. The relative effects on PVC failure of a bordered transparent dressing and a securement device have been assessed in only one small study and these were unclear. There was very low quality evidence from the same single study of less frequent dislodgement or accidental catheter removal with bordered transparent dressings than securement devices (RR 0.14, 95% CI 0.03 to 0.63) but more phlebitis with bordered dressings (RR 8.11, 95% CI 1.03 to 64.02) (very low quality evidence). A small single study compared bordered transparent dressings with tape and found very low quality evidence of more PVC failure with the bordered dressing (RR 1.84, 95% CI 1.08 to 3.11) but the relative effects on dislodgement were not clear (very low quality evidence). The relative effects of transparent dressings and a sticking plaster have only been compared in one small study and are unclear. More high quality RCTs are required to determine the relative effects of alternative PVC dressings and securement devices. AUTHORS'
conclusionsIt is not clear if any one dressing or securement device is better than any other in securing peripheral venous catheters. There is a need for further, independent high quality trials to evaluate the many traditional as well as the newer, high use products. Given the large cost differences between some different dressings and securement devices, future trials should include a robust cost-effectiveness analysis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.