Evidence map›Paper›PMID 26064193›Full record

ArticleBiomicrofluidics2015

Deformability-based circulating tumor cell separation with conical-shaped microfilters: Concept, optimization, and design criteria.

Mohammad Aghaamoo, Zhifeng Zhang, Xiaolin Chen, Jie Xu

Abstract read
In one paragraph

Article in Biomicrofluidics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Review
  2. Review
  3. Early Diagnosis and Screening for Lung Cancer.Cold Spring Harbor perspectives in medicine · 2021
    Review
  4. Article
  5. Review
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Probing Cell Deformability via Acoustically Actuated Bubbles.Small (Weinheim an der Bergstrasse, Germany) · 2016
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mohammad AghaamooDepartment of Mechanical Engineering, Washington State University , Vancouver, Washington 98686, USA.ORCID 0000-0002-4081-6763
Zhifeng ZhangDepartment of Mechanical Engineering, Washington State University , Vancouver, Washington 98686, USA.ORCID 0000-0001-7333-3779
Xiaolin ChenDepartment of Mechanical Engineering, Washington State University , Vancouver, Washington 98686, USA.
Jie XuDepartment of Mechanical and Industrial Engineering, University of Illinois at Chicago , Chicago, Illinois 60607, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Circulating tumor cells (CTCs) separation technology has made positive impacts on cancer science in many aspects. The ability of detecting and separating CTCs can play a key role in early cancer detection and treatment. In recent years, there has been growing interest in using deformability-based CTC separation microfilters due to their simplicity and low cost. Most of the previous studies in this area are mainly based on experimental work. Although experimental research provides useful insights in designing CTC separation devices, there is still a lack of design guidelines based on fundamental understandings of the cell separation process in the filters. While experimental efforts face challenges, especially microfabrication difficulties, we adopt numerical simulation here to study conical-shaped microfilters using deformability difference between CTCs and blood cells for the separation process. We use the liquid drop model for modeling a CTC passing through such microfilters. The accuracy of the model in predicting the pressure signature of the system is validated by comparing it with previous experiments. Pressure-deformability analysis of the cell going through the channel is then carried out in detail in order to better understand how a CTC behaves throughout the filtration process. Different system design criteria such as system throughput and unclogging of the system are discussed. Specifically, pressure behavior under different system throughput is analyzed. Regarding the unclogging issue, we define pressure ratio as a key parameter representing the ability to overcome clogging in such CTC separation devices and investigate the effect of conical angle on the optimum pressure ratio. Finally, the effect of unclogging applied pressure on the system performance is examined. Our study provides detailed understandings of the cell separation process and its characteristics, which can be used for developing more efficient CTC separation devices.

Identifiers

PMID26064193
PMCPMC4457662

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.