ArticleBiomicrofluidics2015
Deformability-based circulating tumor cell separation with conical-shaped microfilters: Concept, optimization, and design criteria.
Article in Biomicrofluidics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed.
- Mechanical deformation and death of circulating tumor cells in the bloodstream.Cancer metastasis reviews · 2024Review
- Biomechanics of circulating cellular and subcellular bioparticles: beyond separation.Cell communication and signaling : CCS · 2024Review
- Early Diagnosis and Screening for Lung Cancer.Cold Spring Harbor perspectives in medicine · 2021Review
- A data-driven approach to modeling cancer cell mechanics during microcirculatory transport.Scientific reports · 2021Article
- Detection of circulating tumor cells: Advances and critical concerns.Oncology letters · 2021Review
- EMT-Associated Heterogeneity in Circulating Tumor Cells: Sticky Friends on the Road to Metastasis.Cancers · 2020Review
- Acoustic Cell Separation Based on Density and Mechanical Properties.Journal of biomechanical engineering · 2020Article
- Recent advances in microfluidic methods in cancer liquid biopsy.Biomicrofluidics · 2019Review
- On the transport of particles/cells in high-throughput deterministic lateral displacement devices: Implications for circulating tumor cell separation.Biomicrofluidics · 2019Article
- Biophysical Insights on the Enrichment of Cancer Cells from Whole Blood by (Affinity) Filtration.Scientific reports · 2019Article
- A Triplet Parallelizing Spiral Microfluidic Chip for Continuous Separation of Tumor Cells.Scientific reports · 2018Article
- Circulating cell-free DNA and circulating tumor cells, the "liquid biopsies" in ovarian cancer.Journal of ovarian research · 2017Review
- Probing Cell Deformability via Acoustically Actuated Bubbles.Small (Weinheim an der Bergstrasse, Germany) · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Circulating tumor cells (CTCs) separation technology has made positive impacts on cancer science in many aspects. The ability of detecting and separating CTCs can play a key role in early cancer detection and treatment. In recent years, there has been growing interest in using deformability-based CTC separation microfilters due to their simplicity and low cost. Most of the previous studies in this area are mainly based on experimental work. Although experimental research provides useful insights in designing CTC separation devices, there is still a lack of design guidelines based on fundamental understandings of the cell separation process in the filters. While experimental efforts face challenges, especially microfabrication difficulties, we adopt numerical simulation here to study conical-shaped microfilters using deformability difference between CTCs and blood cells for the separation process. We use the liquid drop model for modeling a CTC passing through such microfilters. The accuracy of the model in predicting the pressure signature of the system is validated by comparing it with previous experiments. Pressure-deformability analysis of the cell going through the channel is then carried out in detail in order to better understand how a CTC behaves throughout the filtration process. Different system design criteria such as system throughput and unclogging of the system are discussed. Specifically, pressure behavior under different system throughput is analyzed. Regarding the unclogging issue, we define pressure ratio as a key parameter representing the ability to overcome clogging in such CTC separation devices and investigate the effect of conical angle on the optimum pressure ratio. Finally, the effect of unclogging applied pressure on the system performance is examined. Our study provides detailed understandings of the cell separation process and its characteristics, which can be used for developing more efficient CTC separation devices.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.