Evidence map›Paper›PMID 26057383›Full record

ArticlePloS one2015

Dialyzer Reuse and Outcomes of High Flux Dialysis.

Christos Argyropoulos, Maria-Eleni Roumelioti, Abdus Sattar, John A Kellum, Lisa Weissfeld, Mark L Unruh

Abstract read
In one paragraph

Article in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Article
  5. Review
  6. Review
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Christos ArgyropoulosDepartment of Internal Medicine, Division of Nephrology, University of New Mexico, Albuqurque, New Mexico, United States of America.
Maria-Eleni RoumeliotiDepartment of Internal Medicine, Division of Nephrology, University of New Mexico, Albuqurque, New Mexico, United States of America.
Abdus SattarDepartment of Epidemiology and Biostatistics School of Medicine, Case Western Reserve University, Cleveland, Ohio, United States of America.
John A KellumDepartment of Critical Care Medicine, CRISMA Laboratory, University of Pittsburgh, Pittsburgh, Pennsylvania, United States of America.
Lisa WeissfeldDepartment of Critical Care Medicine, CRISMA Laboratory, University of Pittsburgh, Pittsburgh, Pennsylvania, United States of America; Department of Biostatistics University of Pittsburgh, Pittsburgh, Pennsylvania, United States of America.
Mark L UnruhDepartment of Internal Medicine, Division of Nephrology, University of New Mexico, Albuqurque, New Mexico, United States of America.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe bulk of randomized trial evidence for the expanding use of High Flux (HF) hemodialysis worldwide comes from two randomized controlled trials, one of which (HEMODIALYSIS, HEMO) allowed, while the other (Membrane Outcomes Permeability, MPO) excluded, the reuse of membranes. It is not known whether dialyzer reuse has a differential impact on outcomes with HF vs low flyx (LF) dialyzers.

methodsProportional Hazards Models and Joint Models for longitudinal measures and survival outcomes were used in HEMO to analyze the relationship between β2-microglobulin (β2M) concentration, flux, and reuse. Meta-analysis and regression techniques were used to synthesize the evidence for HF dialysis from HEMO and MPO.

findingsIn HEMO, minimally reused (< 6 times) HF dialyzers were associated with a hazard ratio (HR) of 0.67 (95% confidence interval, 95%CI: 0.48-0.92, p = 0.015), 0.64 (95%CI: 0.44 - 0.95, p = 0.03), 0.61 (95%CI: 0.41 - 0.90, p = 0.012), 0.53 (95%CI: 0.28 - 1.02, p = 0.057) relative to minimally reused LF ones for all cause, cardiovascular, cardiac and infectious mortality respectively. These relationships reversed for extensively reused membranes (p for interaction between reuse and flux < 0.001, p = 0.005) for death from all cause and cardiovascular causes, while similar trends were noted for cardiac and infectious mortality (p of interaction between reuse and flux of 0.10 and 0.08 respectively). Reduction of β2M explained only 1/3 of the effect of minimally reused HF dialyzers on all cause mortality, while non-β2M related factors explained the apparent attenuation of the benefit with more extensively reused dialyzers. Meta-regression of HEMO and MPO estimated an adjusted HR of 0.63 (95% CI: 0.51-0.78) for non-reused HF dialyzers compared with non-reused LF membranes.

conclusionsThis secondary analysis and synthesis of two large hemodialysis trials supports the widespread use of HF dialyzers in clinical hemodialysis over the last decade. A mechanistic understanding of the effects of HF dialysis and the reuse process on dialyzers may suggest novel biomarkers for uremic toxicity and may accelerate membrane technology innovations that will improve patient outcomes.

Indexed as

beta 2-MicroglobulinFemaleHumansMaleMembranes, ArtificialMeta-Analysis as TopicMiddle AgedModels, TheoreticalPermeabilityRenal DialysisSurvival AnalysisTreatment Outcomebeta 2-MicroglobulinMembranes, Artificial

Identifiers

PMID26057383
PMCPMC4461247

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.