ArticleHeart and vessels2016

Echocardiographically derived effective valve opening area in mitral prostheses: a comparative analysis of various calculations using continuity equation and pressure half time method.

Nikola Bogunovic, Dieter Horstkotte, Lothar Faber, Lukas Bogunovic, Frank van Buuren

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Heart and vessels, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Nikola BogunovicDepartment of Cardiology, Heart and Diabetes Centre North Rhine-Westphalia, Ruhr University Bochum, Georgstr. 11, 32545, Bad Oeynhausen, Germany. bogu@echoforum.de.
Dieter HorstkotteDepartment of Cardiology, Heart and Diabetes Centre North Rhine-Westphalia, Ruhr University Bochum, Georgstr. 11, 32545, Bad Oeynhausen, Germany.
Lothar FaberDepartment of Cardiology, Heart and Diabetes Centre North Rhine-Westphalia, Ruhr University Bochum, Georgstr. 11, 32545, Bad Oeynhausen, Germany.
Lukas BogunovicDepartment of Physics, University of Bielefeld, Bielefeld, Germany.
Frank van BuurenDepartment of Cardiology, Heart and Diabetes Centre North Rhine-Westphalia, Ruhr University Bochum, Georgstr. 11, 32545, Bad Oeynhausen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Detection of dysfunctional mitral valve prostheses (MP) remains complex even though being optimized by considering echocardiographically derived prosthetic effective orifice area (VA). The purpose was to compare VA in MP, calculated by the continuity equation (CE) using peak velocities (CEVpeak), mean velocities (CEVmean), velocity-time integrals (CEVTI) and the pressure half time method using 220 ms as constant first (PHT220) as well as optimized constants. In 267 consecutive patients with normally functioning MP, we investigated VA within the first postoperative month. With increasing prosthetic sizes, mean VA values also increase in all calculations. The statistical curves demonstrate no significant difference in graphical steepness but show different levels. Comparison of mean VA showed the known systematic higher values of PHT220 and significantly decreased results when using CEVTI. This systematic difference between mean VA applying PHT220 versus CEVTI is approximately 1.0 cm(2) for all prosthetic sizes. Calculations via CEVpeak were close to the results of CEVTI. CEVmean produced values, which graphically correspond to the PHT220 curve. Only PHT220 detected the constructional equal prosthetic inner ring width between 29 and 31 mm. To compensate the systematic difference between CEVTI and PHT220, an optimized constant of 140 ms was calculated to be applied in PHT (PHT140). VA is a robust and, therefore, preferable parameter for investigating MP. If needed, both CE and PHT are applicable with a systematical difference between CEVTI and PHT220. An optimized constant of 140 ms (PHT140) should be applied when calculating VA of mitral valve prostheses via PHT.

Indexed as

Heart Valve ProsthesisHemodynamicsModels, CardiovascularAdolescentAdultAgedAged, 80 and overAlgorithmsChildChild, PreschoolEchocardiography, Doppler, PulsedEchocardiography, TransesophagealFemaleHeart Valve Prosthesis ImplantationHumansImage Interpretation, Computer-AssistedContinuity equationEchocardiographyEffective opening areaHemodynamicsPressure half timeValve prosthesis