Performance assessment of a NaI(Tl) gamma counter for PET applications with methods for improved quantitative accuracy and greater standardization.

Martin A Lodge, Daniel P Holt, Paul E Kinahan, Dean F Wong, Richard L Wahl

Abstract read
In one paragraph

Article in EJNMMI physics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. An Overview of In Vitro Assays ofDiagnostics (Basel, Switzerland) · 2023
    Review
  3. Measurement of PET Quantitative Bias In Vivo.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2021
    Article
  4. ZR-75-1 breast cancer models to study the utility ofTranslational cancer research · 2021
    Article
  5. Article
  6. Article
  7. Primary standardization ofApplied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2020
    Article
  8. Article
  9. Article
  10. Article
  11. Evaluation of Cross-CalibratedTomography (Ann Arbor, Mich.) · 2016
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Martin A LodgeDivision of Nuclear Medicine, The Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Daniel P HoltDivision of Nuclear Medicine, The Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Paul E KinahanDepartment of Radiology, University of Washington, Seattle, WA, USA.
Dean F WongDivision of Nuclear Medicine, The Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Richard L WahlDepartment of Radiology, Washington University School of Medicine, St. Louis, MO, USA.

Funding

Multi-Modality Quantitiative Imaging for Evaluation of Response to Cancer TherapyU01CA140204 · NCI · JOHNS HOPKINS UNIVERSITY · PI DU, YONG, SOLNES, LILJA · 2011 to 2022
$6.1M
Advanced PET/CT Imaging for Improving Clinical TrialsU01CA148131 · NCI · UNIVERSITY OF WASHINGTON · PI KINAHAN, PAUL E., LINDEN, HANNAH M · 2010 to 2019
$6.0M
NCI NIH HHS U01 CA140204NCI NIH HHS U01 CA148131
6 · The paper itself

Abstract

backgroundAlthough NaI(Tl) gamma counters play an important role in many quantitative positron emission tomography (PET) protocols, their calibration for positron-emitting samples has not been standardized across imaging sites. In this study, we characterized the operational range of a gamma counter specifically for positron-emitting radionuclides, and we assessed the role of traceable (68)Ge/(68)Ga sources for standardizing system calibration.

methodsA NaI(Tl) gamma counter was characterized with respect to count rate performance, adequacy of detector shielding, system stability, and sample volume effects using positron-emitting radionuclides (409- to 613-keV energy window). System efficiency was measured using (18)F and compared with corresponding data obtained using a long-lived (68)Ge/(68)Ga source that was implicitly traceable to a national standard.

resultsOne percent count loss was measured at 450 × 10(3) counts per minute. Penetration of the detector shielding by 511-keV photons gave rise to a negligible background count rate. System stability tests showed a coefficient of variation of 0.13% over 100 days. For a sample volume of 4 mL, the efficiencies relative to those at 0.1 mL were 0.96, 0.94, 0.91, 0.78, and 0.72 for (11)C, (18)F, (125)I, (99m)Tc, and (51)Cr, respectively. The efficiency of a traceable (68)Ge/(68)Ga source was 30.1% ± 0.07% and was found to be in close agreement with the efficiency for (18)F after consideration of the different positron fractions.

conclusionsLong-lived (68)Ge/(68)Ga reference sources, implicitly traceable to a national metrology institute, can aid standardization of gamma counter calibration for (18)F. A characteristic feature of positron emitters meant that accurate calibration could be maintained over a wide range of sample volumes by using a narrow energy window centered on the 511-keV peak.

Indexed as

CalibrationEfficiencyGamma counterPositron emission tomographySample volumeStandardizationWell counter

Identifiers

PMID26046011
PMCPMC4452125

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.