SynthesisThe Cochrane database of systematic reviews2015
Computed tomography versus magnetic resonance imaging versus bone scintigraphy for clinically suspected scaphoid fractures in patients with negative plain radiographs.
Synthesis in The Cochrane database of systematic reviews, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 39 papers, 6 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
39 citing papers in PubMed, 6 syntheses or guidelines pooled it, 112 citations in OpenAlex.
- Variation in definitions of scaphoid fracture on MRI scans for suspected fracture: a systematic review.The Journal of hand surgery, European volume · 2026Pooled it
- The use of cone-beam computed tomography (CBCT) in radiocarpal fractures: a diagnostic test accuracy meta-analysis.Skeletal radiology · 2022Pooled it
- Diagnostic performance of cone-beam computed tomography for scaphoid fractures: a systematic review and diagnostic meta-analysis.Scientific reports · 2021Pooled it
- Diagnostic accuracy of history taking, physical examination and imaging for phalangeal, metacarpal and carpal fractures: a systematic review update.BMC musculoskeletal disorders · 2020Pooled it
- Ultrasound for diagnosing radiographically occult scaphoid fracture.Skeletal radiology · 2018Pooled it
- The diagnostic accuracy of cross-sectional imaging for detecting acute scaphoid fractures in children: a systematic review.The British journal of radiology · 2018Pooled it
- Interdisciplinary consensus statements on imaging of scaphoid fractures.European radiology · 2026Article
- Imaging findings of overuse wrist injuries in young artistic gymnasts.Skeletal radiology · 2026Review
- Commentary: Accuracy of Clinical Examination in Suspected Pediatric Scaphoid Fractures-A Systematic Review.Plastic surgery (Oakville, Ont.) · 2026Article
- Radiological Diagnosis of Suspected Scaphoid Fractures in Children: A Systematic Review.Plastic surgery (Oakville, Ont.) · 2026Article
- Soong Classification Using Radiographs Only Moderately Correlates With Distal Radius Plate Position on Computed Tomography.Hand (New York, N.Y.) · 2025Article
- Understanding Pediatric Clinical Scaphoid Injuries: A Prospective Radiological Study.Plastic surgery (Oakville, Ont.) · 2025Article
- Treatment Options, Return to Play, and Functional Performance after Operatively and Non-operatively Managed Acute Scaphoid Fractures.Current reviews in musculoskeletal medicine · 2025Review
- Trends in the Use of Weightbearing Computed Tomography.Journal of clinical medicine · 2024Review
- Diagnostic Value of Ultrasound for Sternal Fractures in Patients with Trauma Experiencing Anterior Chest Wall Pain.Journal of clinical medicine · 2024Article
- An Umbrella Review and Updated Meta-Analysis of Imaging Modalities in Occult Scaphoid and Hip and Femoral Fractures.Journal of clinical medicine · 2024Review
- Artificial intelligence for MRI stroke detection: a systematic review and meta-analysis.Insights into imaging · 2024Review
- Early MRI for Pediatric Wrist Injuries-Prospective Case Series of 150 Cases.Journal of wrist surgery · 2023Article
- Transverse carpal ligament tear at the trapezial ridge without fracture - the "trapezial ridge line" sign: two case reports.BJR case reports · 2023Article
- Virtual non-calcium dual-energy CT: clinical applications.European radiology experimental · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIn clinically suspected scaphoid fractures, early diagnosis reduces the risk of non-union and minimises loss in productivity resulting from unnecessary cast immobilisation. Since initial radiographs do not exclude the possibility of a fracture, additional imaging is needed. Computed tomography (CT), magnetic resonance imaging (MRI) and bone scintigraphy (BS) are widely used to establish a definitive diagnosis, but there is uncertainty about the most appropriate method.
objectivesThe primary aim of this study is to identify the most suitable diagnostic imaging strategy for identifying clinically suspected fractures of the scaphoid bone in patients with normal radiographs. Therefore we looked at the diagnostic performance characteristics of the most used imaging modalities for this purpose: computed tomography, magnetic resonance imaging and bone scintigraphy. SEARCH
methodsIn July 2012, we searched the Cochrane Register of Diagnostic Test Accuracy Studies, MEDLINE, EMBASE, the Database of Abstracts of Reviews of Effects, the Cochrane Central Register of Controlled Trials, the NHS Economic Evaluation Database. In September 2012, we searched MEDION, ARIF, Current Controlled Trials, the World Health Organization (WHO) International Clinical Trials Registry Platform, conference proceedings and reference lists of all articles. SELECTION CRITERIA: We included all prospective or retrospective studies involving a consecutive series of patients of all ages that evaluated the accuracy of BS, CT or MRI, or any combination of these, for diagnosing suspected scaphoid fractures. We considered the use of one or two index tests or six-week follow-up radiographs as adequate reference standards. DATA COLLECTION AND ANALYSIS: Two review authors independently screened titles and abstracts and assessed full-text reports of potentially eligible studies. The same authors extracted data from full-text reports and assessed methodological quality using the QUADAS checklist. For each index test, estimates of sensitivity and specificity from each study were plotted in ROC space; and forest plots were constructed for visual examination of variation in test accuracy. We performed meta-analyses using the HSROC model to produce summary estimates of sensitivity and specificity. MAIN
resultsWe included 11 studies that looked at diagnostic accuracy of one or two index tests: four studies (277 suspected fractures) looked at CT, five studies (221 suspected fractures) looked at MRI and six studies (543 suspected fractures) looked at BS. Four of the studies made direct comparisons: two studies compared CT and MRI, one study compared CT and BS, and one study compared MRI and BS. Overall, the studies were of moderate to good quality, but relevant clinical information during evaluation of CT, MRI or BS was mostly unclear or unavailable.As few studies made direct comparisons between tests with the same participants, our results are based on data from indirect comparisons, which means that these results are more susceptible to bias due to confounding. Nonetheless, the direct comparisons showed similar patterns of differences in sensitivity and specificity as for the pooled indirect comparisons.Summary sensitivity and specificity of CT were 0.72 (95% confidence interval (CI) 0.36 to 0.92) and 0.99 (95% CI 0.71 to 1.00); for MRI, these were 0.88 (95% CI 0.64 to 0.97) and 1.00 (95% CI 0.38 to 1.00); for BS, these were 0.99 (95% CI 0.69 to 1.00) and 0.86 (95% CI 0.73 to 0.94). Indirect comparisons suggest that diagnostic accuracy of BS was significantly higher than CT and MRI; and CT and MRI have comparable diagnostic accuracy. The low prevalence of a true fracture among suspected fractures (median = 20%) means the lower specificity for BS is problematic. For example, in a cohort of 1000 patients, 112 will be over-treated when BS is used for diagnosis. If CT is used, only 8 will receive unnecessary treatment. In terms of missed fractures, BS will miss 2 fractures and CT will miss 56 fractures. AUTHORS'
conclusionsAlthough quality of the included studies is moderate to good, findings are based on only 11 studies and the confidence intervals for the summary estimates are wide for all three tests. Well-designed direct comparison studies including CT, MRI and BS could give valuable additional information.Bone scintigraphy is statistically the best diagnostic modality to establish a definitive diagnosis in clinically suspected fractures when radiographs appear normal. However, physicians must keep in mind that BS is more invasive than the other modalities, with safety issues due to level of radiation exposure, as well as diagnostic delay of at least 72 hours. The number of overtreated patients is substantially lower with CT and MRI.Prior to performing comparative studies, there is a need to raise the initially detected prevalence of true fractures in order to reduce the effect of the relatively low specificity in daily practice. This can be achieved by improving clinical evaluation and initial radiographical assessment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.