Evidence map›Paper›PMID 26026693›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2015

Evaluation of alignment in total knee arthroplasty: a prospective study.

K S Manjunath, K G Gopalakrishna, G Vineeth

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Mid-term results of an anatomic total knee replacement design.Archives of orthopaedic and trauma surgery · 2024
    Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Weight-bearing radiography depends on limb loading.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2019
    Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

K S ManjunathDepartment of Orthopaedics, Bangalore Medical College and Research Institute, Fort, K. R. Road, Bangalore, 560002, India, kmanjunath215@gmail.com.
K G Gopalakrishna
G Vineeth

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSuccessful results of knee arthroplasty demand precise surgical technique, sound implant design, kinematics, appropriate materials and patient compliance with rehabilitation. The precision with which the implants are placed directly affects patient outcome as implant position and alignment influence the stability, durability and patellar tracking. Evaluating the alignment in total knee arthroplasty and functional outcome with respect to the alignment is the need of the hour. AIM AND OBJECTIVE OF THE STUDY: (1) To evaluate the accuracy of the overall limb alignment and component alignment in jig-assisted TKR. (2) To evaluate the functional outcome with respect to the alignment parameters. METHODOLOGY: This is a prospective study of 120 knees in 80 patients that underwent total knee replacement at Victoria and Bowring and Lady Curzon hospitals. Patients were selected according to the inclusion and exclusion criteria and evaluated using knee society score at regular follow-up. Preoperative and postoperative standing 'long-leg radiographs' and postoperative CT scans were taken from all the patients. In our study, we had 54 female patients and 26 male patients. Indications were OA in 72 and RA in 48 knees. The average follow-up period was 36 months.

resultsPreoperatively, all the patients had moderate to severe pain. Mechanical and tibiofemoral axes were outside the acceptable range. Postoperatively, with respect to mechanical axis, the inliers had significantly better knee score (p = 0.026) compared to the outliers. But the functional score did not show any significant difference between these two groups (p = 0.2093). Inliers in tibiofemoral axis alignment parameter had extremely significant better knee score (p = 0.0001) and also functional score (p = 0.0082) compared to outliers group. Sagittal and rotational femoral component angles in all 120 cases were coming within the 'inliers group'. Similarly, the sagittal, the coronal and the rotational component angles of tibia were also coming under inliers group in all 120 replaced knees.

conclusionAligning the mechanical axis, tibiofemoral angle within (0° ± 3°) and placement of prostheses within (0° ± 3°) to the normal alignment in all the three planes significantly produce excellent result with respect to functional outcome.

Indexed as

AgedArthritis, RheumatoidArthroplasty, Replacement, KneeBiomechanical PhenomenaFemaleHumansKnee JointMaleMiddle AgedOsteoarthritis, KneeProspective StudiesRange of Motion, ArticularTomography, X-Ray ComputedTreatment Outcome

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.