Evidence map›Paper›PMID 26022966›Full record

ArticleActa biomaterialia2015

Shear lag sutures: Improved suture repair through the use of adhesives.

Stephen W Linderman, Ioannis Kormpakis, Richard H Gelberman, Victor Birman, Ulrike G K Wegst, Guy M Genin, Stavros Thomopoulos

Abstract read
In one paragraph

Article in Acta biomaterialia, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Effect of connective tissue growth factor delivered via porous sutures on the proliferative stage of intrasynovial tendon repair.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2018
    Article
  10. Article
  11. Cell and Biologic-Based Treatment of Flexor Tendon Injuries.Operative techniques in orthopaedics · 2016
    Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Stephen W LindermanDepartment of Orthopaedic Surgery, Washington University, St Louis, MO 63110, United States; Department of Biomedical Engineering, Washington University, St Louis, MO 63130, United States.
Ioannis KormpakisDepartment of Orthopaedic Surgery, Washington University, St Louis, MO 63110, United States.
Richard H GelbermanDepartment of Orthopaedic Surgery, Washington University, St Louis, MO 63110, United States.
Victor BirmanEngineering Education Center, Missouri University of Science and Technology, St Louis, MO 63131, United States.
Ulrike G K WegstThayer School of Engineering, Dartmouth College, Hanover, NH 03755, United States.
Guy M GeninDepartment of Mechanical Engineering and Materials Science, Washington University, St Louis, MO 63130, United States. Electronic address: gening@seas.wustl.edu.
Stavros ThomopoulosDepartment of Orthopaedic Surgery, Washington University, St Louis, MO 63110, United States; Department of Biomedical Engineering, Washington University, St Louis, MO 63130, United States; Department of Mechanical Engineering and Materials Science, Washington University, St Louis, MO 63130, United States. Electronic address: thomopouloss@wustl.edu.

Funding

NATIONAL RESEARCH SERVICE AWARD-MEDICAL SCIENTISTT32GM007200 · NIGMS · WASHINGTON UNIVERSITY · PI YOKOYAMA, WAYNE M. · 1985 to 2024
$59.8M
The Role of the Osteoblast Secretome in Bone FormationP30AR057235 · NIAMS · WASHINGTON UNIVERSITY · PI SILVA, MATTHEW J · 2009 to 2018
$5.7M
Enhanced Tendon Healing Through Growth Factor and Cell TherapiesR01AR062947 · NIAMS · WASHINGTON UNIVERSITY · PI GELBERMAN, RICHARD H, THOMOPOULOS, STAVROS · 2012 to 2022
$5.5M
Skeletal Disorders Training ProgramT32AR060719 · NIAMS · WASHINGTON UNIVERSITY · PI Roberto Civitelli · 2011 to 2026
$4.6M
Cross-scale interactions between mineral and collagen for tendon-bone attachmentU01EB016422 · NIBIB · WASHINGTON UNIVERSITY · PI GENIN, GUY M, THOMOPOULOS, STAVROS · 2013 to 2017
$2.4M
NIAMS NIH HHS P30 AR057235NIAMS NIH HHS R01 AR062947NIAMS NIH HHS T32 AR060719NIBIB NIH HHS U01 EB016422NIGMS NIH HHS T32 GM007200
6 · The paper itself

Abstract

Suture materials and surgical knot tying techniques have improved dramatically since their first use over five millennia ago. However, the approach remains limited by the ability of the suture to transfer load to tissue at suture anchor points. Here, we predict that adhesive-coated sutures can improve mechanical load transfer beyond the range of performance of existing suture methods, thereby strengthening repairs and decreasing the risk of failure. The mechanical properties of suitable adhesives were identified using a shear lag model. Examination of the design space for an optimal adhesive demonstrated requirements for strong adhesion and low stiffness to maximize the strength of the adhesive-coated suture repair construct. To experimentally assess the model, we evaluated single strands of sutures coated with highly flexible cyanoacrylates (Loctite 4903 and 4902), cyanoacrylate (Loctite QuickTite Instant Adhesive Gel), rubber cement, rubber/gasket adhesive (1300 Scotch-Weld Neoprene High Performance Rubber & Gasket Adhesive), an albumin-glutaraldehyde adhesive (BioGlue), or poly(dopamine). As a clinically relevant proof-of-concept, cyanoacrylate-coated sutures were then used to perform a clinically relevant flexor digitorum tendon repair in cadaver tissue. The repair performed with adhesive-coated suture had significantly higher strength compared to the standard repair without adhesive. Notably, cyanoacrylate provides strong adhesion with high stiffness and brittle behavior, and is therefore not an ideal adhesive for enhancing suture repair. Nevertheless, the improvement in repair properties in a clinically relevant setting, even using a non-ideal adhesive, demonstrates the potential for the proposed approach to improve outcomes for treatments requiring suture fixation. Further study is necessary to develop a strongly adherent, compliant adhesive within the optimal design space described by the model.

Indexed as

Models, BiologicalSuturesSuture TechniquesAdhesivenessCadaverCoated Materials, BiocompatibleCombined Modality TherapyComputer SimulationHumansShear StrengthStress, MechanicalTendon InjuriesTensile StrengthTissue AdhesivesTreatment OutcomeWound HealingCoated Materials, BiocompatibleTissue AdhesivesAdhesiveBiomechanicsFlexor tendonShear lagSuture

Identifiers

PMID26022966
PMCPMC4522236

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.