Evidence map›Paper›PMID 26020102›Full record

ArticleTissue engineering. Part A2015

Gas Transfer in Cellularized Collagen-Membrane Gas Exchange Devices.

Justin H Lo, Erik K Bassett, Elliot J N Penson, David M Hoganson, Joseph P Vacanti

Abstract read
In one paragraph

Article in Tissue engineering. Part A, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Justin H Lo1 Department of Surgery, Center for Regenerative Medicine , Massachusetts General Hospital, Boston, Massachusetts.
Erik K Bassett1 Department of Surgery, Center for Regenerative Medicine , Massachusetts General Hospital, Boston, Massachusetts.
Elliot J N Penson1 Department of Surgery, Center for Regenerative Medicine , Massachusetts General Hospital, Boston, Massachusetts.
David M Hoganson1 Department of Surgery, Center for Regenerative Medicine , Massachusetts General Hospital, Boston, Massachusetts.
Joseph P Vacanti1 Department of Surgery, Center for Regenerative Medicine , Massachusetts General Hospital, Boston, Massachusetts.

Funding

Medical Scientist Training ProgramT32GM007753 · NIGMS · HARVARD UNIVERSITY (MEDICAL SCHOOL) · PI WALENSKY, LOREN DAVID · 1985 to 2021
$50.0M
Biliary morphogenesis and bile canaliculi integrationF32DK076349 · NIDDK · MASSACHUSETTS GENERAL HOSPITAL · PI HOGANSON, DAVID · 2006 to 2007
$99k
NIDDK NIH HHS F32 DK076349-01NIGMS NIH HHS T32 GM007753NIGMS NIH HHS T32GM007753
6 · The paper itself

Abstract

Chronic lower respiratory disease is highly prevalent in the United States, and there remains a need for alternatives to lung transplant for patients who progress to end-stage lung disease. Portable or implantable gas oxygenators based on microfluidic technologies can address this need, provided they operate both efficiently and biocompatibly. Incorporating biomimetic materials into such devices can help replicate native gas exchange function and additionally support cellular components. In this work, we have developed microfluidic devices that enable blood gas exchange across ultra-thin collagen membranes (as thin as 2 μm). Endothelial, stromal, and parenchymal cells readily adhere to these membranes, and long-term culture with cellular components results in remodeling, reflected by reduced membrane thickness. Functionally, acellular collagen-membrane lung devices can mediate effective gas exchange up to ∼288 mL/min/m(2) of oxygen and ∼685 mL/min/m(2) of carbon dioxide, approaching the gas exchange efficiency noted in the native lung. Testing several configurations of lung devices to explore various physical parameters of the device design, we concluded that thinner membranes and longer gas exchange distances result in improved hemoglobin saturation and increases in pO2. However, in the design space tested, these effects are relatively small compared to the improvement in overall oxygen and carbon dioxide transfer by increasing the blood flow rate. Finally, devices cultured with endothelial and parenchymal cells achieved similar gas exchange rates compared with acellular devices. Biomimetic blood oxygenator design opens the possibility of creating portable or implantable microfluidic devices that achieve efficient gas transfer while also maintaining physiologic conditions.

Indexed as

Lab-On-A-Chip DevicesMembranes, ArtificialCell AdhesionCollagenHumansHuman Umbilical Vein Endothelial CellsOxygenCollagenMembranes, ArtificialOxygen

Identifiers

PMID26020102
PMCPMC4529054

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked