Evidence map›Paper›PMID 26016913›Full record

ArticleSensors (Basel, Switzerland)2015

Amorphous silicon p-i-n structure acting as light and temperature sensor.

Giampiero de Cesare, Augusto Nascetti, Domenico Caputo

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Giampiero de CesareDepartment of Information Engineering, Electronics and Telecommunications, "La Sapienza" University of Rome, via Eudossiana 18, 00184 Rome, Italy. decesare@diet.uniroma1.it.
Augusto NascettiDepartment of Astronautics, Electrical and Energetic Engineering, "La Sapienza" University of Rome, via Eudossiana 18, 00184 Rome, Italy. augusto.nascetti@uniroma1.it.
Domenico CaputoDepartment of Information Engineering, Electronics and Telecommunications, "La Sapienza" University of Rome, via Eudossiana 18, 00184 Rome, Italy. caputo@diet.uniroma1.it.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this work, we propose a multi-parametric sensor able to measure both temperature and radiation intensity, suitable to increase the level of integration and miniaturization in Lab-on-Chip applications. The device is based on amorphous silicon p-doped/intrinsic/n-doped thin film junction. The device is first characterized as radiation and temperature sensor independently. We found a maximum value of responsivity equal to 350 mA/W at 510 nm and temperature sensitivity equal to 3.2 mV/K. We then investigated the effects of the temperature variation on light intensity measurement and of the light intensity variation on the accuracy of the temperature measurement. We found that the temperature variation induces an error lower than 0.55 pW/K in the light intensity measurement at 550 nm when the diode is biased in short circuit condition, while an error below 1 K/µW results in the temperature measurement when a forward bias current higher than 25 µA/cm2 is applied.

Indexed as

amorphous silicon devicesLab-on-Chipphotosensorstemperature sensors

Identifiers

PMID26016913
PMCPMC4507708

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.