Evidence map›Paper›PMID 26014494›Full record

ArticleRadiation oncology (London, England)2015

Surface refraction of sound waves affects calibration of three-dimensional ultrasound.

Hendrik Ballhausen, Bianca Désirée Ballhausen, Martin Lachaine, Minglun Li, Katia Parodi, Claus Belka, Michael Reiner

Abstract read
In one paragraph

Article in Radiation oncology (London, England), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Prefraction displacement and intrafraction drift of the prostate due to perineal ultrasound probe pressure.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2017
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hendrik BallhausenDepartment of Radiation Oncology, University Hospital of Ludwig-Maximilians-University, Marchioninistraße 15, 81377, Munich, Germany. Hendrik.Ballhausen@med.uni-muenchen.de.
Bianca Désirée BallhausenSmall Animal Clinic Haar, Keferloher Strasse 25, 85540, Haar, Germany. Hendrik.Ballhausen@med.lmu.de.
Martin LachaineElekta Ltd, 2050 de Bleury, Montréal, QC, H3A2J5, Canada. Martin.Lachaine@elekta.com.
Minglun LiDepartment of Radiation Oncology, University Hospital of Ludwig-Maximilians-University, Marchioninistraße 15, 81377, Munich, Germany. Minglun.Li@med.uni-muenchen.de.
Katia ParodiDepartment of Experimental Physics, Medical Physics, Ludwig-Maximilians-University, Am Coulombwall 1, 85748, Garching, Germany. Katia.Parodi@physik.uni-muenchen.de.
Claus BelkaDepartment of Radiation Oncology, University Hospital of Ludwig-Maximilians-University, Marchioninistraße 15, 81377, Munich, Germany. Claus.Belka@med.uni-muenchen.de.
Michael ReinerDepartment of Radiation Oncology, University Hospital of Ludwig-Maximilians-University, Marchioninistraße 15, 81377, Munich, Germany. Michael.Reiner@med.uni-muenchen.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThree-dimensional ultrasound (3D-US) is used in planning and treatment during external beam radiotherapy. The accuracy of the technique depends not only on the achievable image quality in clinical routine, but also on technical limitations of achievable precision during calibration. Refraction of ultrasound waves is a known source for geometric distortion, but such an effect was not expected in homogenous calibration phantoms. However, in this paper we demonstrate that the discontinuity of the refraction index at the phantom surface may affect the calibration unless the ultrasound probe is perfectly perpendicular to the phantom.

methodsA calibration phantom was repeatedly scanned with a 3D-US system (Elekta Clarity) by three independent observers. The ultrasound probe was moved horizontally at a fixed angle in the sagittal plane. The resulting wedge shaped volume between probe and phantom was filled with water to couple in the ultrasound waves. Because the speed of sound in water was smaller than the speed of sound in Zerdine, the main component of the phantom, the angle of the ultrasound waves inside the phantom increased. This caused an apparent shift in the calibration features which was recorded as a function of the impeding angle. To confirm the magnitude and temperature dependence, the experiment was repeated by two of the observers with a mixture of ice and water at 0 °C and with thermalized tap water at 21 °C room temperature.

resultsDuring the first series of measurements, a linear dependency of the displacements dx of the calibration features on the angle α of the ultrasound probe was observed. The three observers recorded significantly nonzero (p < 0.0001) and very consistent slopes of dx/dα of 0.12, 0.12, and 0.13 mm/°, respectively.. At 0 °C water temperature, the slope increased to 0.18 ± 0.04 mm/°. This matched the prediction of Snell's law of 0.185 mm/° for a speed of sound of 1,402 m/s at the melting point of ice. At 21 °C, slopes of 0.11 and 0.12 mm/° were recorded in agreement with the first experiment at about room temperature. The difference to the theoretical expectation of 0.07 mm/° was not significant (p = 0.09).

conclusionsThe surface refraction of sound waves my affect the calibration of three-dimensional ultrasound. The temperature dependence of the effect rules out alternative explanations for the observed shifts in calibration. At room temperature and for a structure that is 10 cm below the water-phantom interface, a tilt of the ultrasound probe of 10° may result in a position reading that is off by more than half a millimeter. Such errors are of the order of other relevant errors typically encountered during the calibration of a 3D-US system. Hence, care must be taken not to tilt the ultrasound probe during calibration.

Indexed as

Phantoms, ImagingCalibrationEquipment DesignHumansImage Processing, Computer-AssistedImaging, Three-DimensionalPatient PositioningRadiotherapyRadiotherapy Planning, Computer-AssistedUltrasonography

Identifiers

PMID26014494
PMCPMC4450514

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.