Evidence map›Paper›PMID 26011598›Full record

ArticlePloS one2015

Effectiveness of a load-imposing device for cyclic stretching of isolated human bronchi: a validation study.

Morgan Le Guen, Emmanuel Naline, Stanislas Grassin-Delyle, Philippe Devillier, Christophe Faisy

Open access · goldAbstract readValidation Study
In one paragraph

Article in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Morgan Le GuenResearch Unit UPRES EA220, University Versailles Saint-Quentin, Hôpital Foch, 40 rue Worth, F-92150, Suresnes, France; Departement of Anesthesiology, Hôpital Foch, 40 rue Worth, F-92150, Suresnes, France.
Emmanuel NalineResearch Unit UPRES EA220, University Versailles Saint-Quentin, Hôpital Foch, 40 rue Worth, F-92150, Suresnes, France.
Stanislas Grassin-DelyleResearch Unit UPRES EA220, University Versailles Saint-Quentin, Hôpital Foch, 40 rue Worth, F-92150, Suresnes, France.
Philippe DevillierResearch Unit UPRES EA220, University Versailles Saint-Quentin, Hôpital Foch, 40 rue Worth, F-92150, Suresnes, France.
Christophe FaisyResearch Unit UPRES EA220, University Versailles Saint-Quentin, Hôpital Foch, 40 rue Worth, F-92150, Suresnes, France; Medical Intensive Care Unit, Hôpital Européen Georges Pompidou, Assistance Publique-Hôpitaux de Paris, University Sorbonne Paris Cité, 20 rue Leblanc, F-75908, Paris, Cedex 15, France.
Hôpital Foch · FRAssistance Publique – Hôpitaux de Paris · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMechanical ventilation may induce harmful effects in the airways of critically ill patients. Nevertheless, the effects of cyclic stretching caused by repetitive inflation-deflation of the bronchial compartment have not been well characterized in humans. The objective of the present study was to assess the effectiveness of a load-imposing device for the cyclic stretching of human bronchi.

methodsIntact bronchial segments were removed from 128 thoracic surgery patients. After preparation and equilibration in an organ bath, bronchi were stretched repetitively and cyclically with a motorized transducer. The peak force imposed on the bronchi was set to 80% of each individual maximum contraction in response to acetylcholine and the minimal force corresponded to the initial basal tone before stretching. A 1-min cycle (stretching for 15 sec, relaxing for 15 sec and resting for 30 sec) was applied over a time period ranging from 5 to 60 min. The device's performance level was assessed and the properties of the stretched bronchi were compared with those of paired, non-stretched bronchi.

resultsDespite the intrinsic capacities of the device, the targets of the tension adjustments remained variable for minimal tension (156-178%) while the peak force set point was unchanged (87-115%). In the stretched bronchi, a time-dependent rise in basal tone (P < .05 vs. non-stretched) was apparent after as little as 5 min of cyclic stretching. The stretch-induced rise in basal tone continued to increase (P < .01) after the stretching had ended. Only 60 min of cyclic stretching was associated with a significant (P < .05) increase in responsiveness to acetylcholine, relative to non-stretched bronchi.

conclusionsLow-frequency, low-force, cyclic loading of human bronchi is associated with elevated basal tone and acetylcholine responsiveness. The present experimental model is likely to be a useful tool for future investigations of the bronchial response to repetitive stress during mechanical ventilation.

Indexed as

Biomechanical PhenomenaBronchiHumansIn Vitro TechniquesModels, BiologicalTime FactorsTissue Expansion DevicesTransducers

Identifiers

PMID26011598
PMCPMC4444237
OpenAlexW367699884

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.