Evidence map›Paper›PMID 26007732›Full record

ArticleSensors (Basel, Switzerland)2015

Highly stable liquid metal-based pressure sensor integrated with a microfluidic channel.

Taekeon Jung, Sung Yang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Review
  12. Soft and Deformable Sensors Based on Liquid Metals.Sensors (Basel, Switzerland) · 2019
    Review
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Taekeon JungDepartment of Medical System Engineering, GIST, Gwangju 500-712, Korea. taekeonjung@gist.ac.kr.
Sung YangDepartment of Medical System Engineering, GIST, Gwangju 500-712, Korea. syang@gist.ac.kr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Pressure measurement is considered one of the key parameters in microfluidic systems. It has been widely used in various fields, such as in biology and biomedical fields. The electrical measurement method is the most widely investigated; however, it is unsuitable for microfluidic systems because of a complicated fabrication process and difficult integration. Moreover, it is generally damaged by large deflection. This paper proposes a thin-film-based pressure sensor that is free from these limitations, using a liquid metal called galinstan. The proposed pressure sensor is easily integrated into a microfluidic system using soft lithography because galinstan exists in a liquid phase at room temperature. We investigated the characteristics of the proposed pressure sensor by calibrating for a pressure range from 0 to 230 kPa (R2 > 0.98) using deionized water. Furthermore, the viscosity of various fluid samples was measured for a shear-rate range of 30-1000 s(-1). The results of Newtonian and non-Newtonian fluids were evaluated using a commercial viscometer and normalized difference was found to be less than 5.1% and 7.0%, respectively. The galinstan-based pressure sensor can be used in various microfluidic systems for long-term monitoring with high linearity, repeatability, and long-term stability.

Indexed as

AlloysCalibrationEquipment DesignMetals, HeavyMicrofluidic Analytical TechniquesPressureViscosityAlloysgalinstanMetals, Heavygalinstanliquid metalmicrofluidicpressure sensorviscosity

Identifiers

PMID26007732
PMCPMC4481972

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.