ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2015
All-polyethylene tibial components are not inferior to metal-backed tibial components in long-term follow-up of knee arthroplasties.
Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03569670 (All-Polyethylene Tibial Components in Total Knee Arthroplasty), which is not on this map. Cited by 5 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
All-Polyethylene Tibial Components in Total Knee Arthroplasty: A Radiostereometric Analysis Comparing Posterior Stabilizing and Condylar Stabilizing Implants
Who cites it
5 citing papers in PubMed, 2 syntheses or guidelines pooled it, 15 citations in OpenAlex.
- All-polyethylene versus metal-backed tibial components in total knee arthroplasty: a meta-analysis of randomized controlled trials.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2023Pooled it
- All-polyethylene versus metal-backed tibial component in total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2017Pooled it
- Implant Preference and Clinical Outcomes of Patients with Staged Bilateral Total Knee Arthroplasty: All-Polyethylene and Contralateral Metal-Backed Tibial Components.Journal of clinical medicine · 2023Article
- Clinical outcomes and survival comparison between NexGen all-poly and its metal-backed equivalent in total knee arthroplasty.International orthopaedics · 2023Article
- Cemented all-poly tibia in resource constrained country, affordable and cost-effective care. Is it applicable at this era? Review article.Annals of medicine and surgery (2012) · 2019Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAll-polyethylene tibias (APT) are under-utilized in most of the Western countries, due to a shift from the original all-polyethylene design to metal-backed tibia (MBT) components. Only few total knee prostheses allow direct comparison between APT and MBT components, due to different geometric designs in many systems. The Depuy PFC Sigma prostheses have a similar geometric design in both the MBT and the APT, and with the same corresponding femoral component, thus allowing an assessment and comparison between APT and MBT components.
methodsThis is a retrospective analysis of a consecutive series of osteoarthritic patients who underwent total knee arthroplasties with at least 10-year follow-up comparing a modern congruent APT component to a modular MBT component of the same design.
resultsSeventy-three patients (81 knees, mean age 73 years) were available for assessment. Among the cohort, three patients had revision surgery (one from the APT group). In total, 73 patients were available for follow-up (59 MBT prostheses and 22 APT prostheses). There were no differences in knee function (Knee Society score, range of motion, stability) or radiographic parameters between the groups. Of the three revisions due to tibial tray loosening, only one was performed in the APT group and two were performed in the MBT group; another revision in the MBT group was due to loosening of both components; none of the revisions were due to septic complications. Ten-year survivorship of both designs was 92 %.
conclusionsWhile function of both designs appears similar, the APT design shows a trend toward requiring fewer revisions and is more cost-effective.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials