Evidence map›Paper›PMID 25993517›Full record

ArticleSensors (Basel, Switzerland)2015

A Colorimetric Enzyme-Linked Immunosorbent Assay (ELISA) Detection Platform for a Point-of-Care Dengue Detection System on a Lab-on-Compact-Disc.

Aung Thiha, Fatimah Ibrahim

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 41 papers.

0numbers the graph read from it
0cells of the map it votes in
41citing papers in PubMed
10.3field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

41 citing papers in PubMed, 139 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. Review
  7. Review
  8. Enhanced Sweat Biosensing with Thread-Embedded Microfluidic Devices.Medical science monitor : international medical journal of experimental and clinical research · 2024
    Article
  9. Review
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Virus Detection: From State-of-the-Art Laboratories to Smartphone-Based Point-of-Care Testing.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2022
    Review
  16. Review
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Aung ThihaDepartment of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia. aungthiha.bme@gmail.com.
Fatimah IbrahimDepartment of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia. fatimah@um.edu.my.
University of Malaya · MY

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The enzyme-linked Immunosorbent Assay (ELISA) is the gold standard clinical diagnostic tool for the detection and quantification of protein biomarkers. However, conventional ELISA tests have drawbacks in their requirement of time, expensive equipment and expertise for operation. Hence, for the purpose of rapid, high throughput screening and point-of-care diagnosis, researchers are miniaturizing sandwich ELISA procedures on Lab-on-a-Chip and Lab-on-Compact Disc (LOCD) platforms. This paper presents a novel integrated device to detect and interpret the ELISA test results on a LOCD platform. The system applies absorption spectrophotometry to measure the absorbance (optical density) of the sample using a monochromatic light source and optical sensor. The device performs automated analysis of the results and presents absorbance values and diagnostic test results via a graphical display or via Bluetooth to a smartphone platform which also acts as controller of the device. The efficacy of the device was evaluated by performing dengue antibody IgG ELISA on 64 hospitalized patients suspected of dengue. The results demonstrate high accuracy of the device, with 95% sensitivity and 100% specificity in detection when compared with gold standard commercial ELISA microplate readers. This sensor platform represents a significant step towards establishing ELISA as a rapid, inexpensive and automatic testing method for the purpose of point-of-care-testing (POCT) in resource-limited settings.

Indexed as

Compact DisksPoint-of-Care SystemsAntibodies, ViralColorimetryDengueDengue VirusEnzyme-Linked Immunosorbent AssayHumansImmunoglobulin GAntibodies, ViralImmunoglobulin Gcolorimetric sensingdengue detectionEnzyme Linked Immunosorbent Assay (ELISA)immunosensorslab-on-a-chip (LOC)Lab-on-Compact Discoptical biosensorspoint-of-care testingsmartphone