Observational studyPloS one2015
Accuracy of pulse oximeters in detecting hypoxemia in patients with chronic thromboembolic pulmonary hypertension.
Observational study in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 23 citations in OpenAlex.
- Early assessment in bulbar-onset amyotrophic lateral sclerosis detects similar rates of nocturnal desaturation and orthopnoea compared to non-bulbar-onset disease.Sleep & breathing = Schlaf & Atmung · 2025Article
- Inter-Night Variability of Nocturnal Pulse Oximetry in People Living With Motor Neuron Disease: A Retrospective Observational Study.Respirology (Carlton, Vic.) · 2025Observational
- Characteristics of pulse oximetry and arterial blood gas in patients with fibrotic interstitial lung disease.BMJ open respiratory research · 2024Article
- Recent Progress in Flexible and Wearable All Organic Photoplethysmography Sensors for SpOAdvanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023Review
- Article
- The influence of short-term high-altitude acclimatization on cerebral and leg tissue oxygenation post-orthostasis.European journal of applied physiology · 2021Article
- Accuracy of two pulse-oximetry measurements for INTELLiVENT-ASV in mechanically ventilated patients: a prospective observational study.Scientific reports · 2021Observational
- Role of interleukin 6 as a predictive factor for a severe course of Covid-19: retrospective data analysis of patients from a long-term care facility during Covid-19 outbreak.BMC infectious diseases · 2021Article
- Comparison of Repetitive Cardiac Output Measurements at Rest and End-Exercise by Direct Fick Using Pulse Oximetry vs. Blood Gases in Patients With Pulmonary Hypertension.Frontiers in medicine · 2021Article
- Recurrent probabilistic neural network-based short-term prediction for acute hypotension and ventricular fibrillation.Scientific reports · 2020Article
- Observational
- A multicentre prospective observational study comparing arterial blood gas values to those obtained by pulse oximeters used in adult patients attending Australian and New Zealand hospitals.BMC pulmonary medicine · 2020Observational
- Onset of Donor Warm Ischemia Time in Donation After Circulatory Death Liver Transplantation: Hypotension or Hypoxia?Liver transplantation : official publication of the American Association for the Study of Liver Diseases and the International Liver Transplantation Society · 2018Article
- Correction: Accuracy of Pulse Oximeters in Detecting Hypoxemia in Patients with Chronic Thromboembolic Pulmonary Hypertension.PloS one · 2015Article
- Article
Corrections and comments
- Erratum issued
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposePulse oximetry is routinely used to continuously and non-invasively monitor arterial oxygen saturation (SaO2). When oxygen saturation by pulse oximeter (SpO2) overestimates SaO2, hypoxemia may be overlooked. We compared the SpO2 - SaO2 differences among three pulse oximeters in patients with chronic thromboembolic pulmonary hypertension (CTEPH) who spent their daily lives in a poor oxygen state. MATERIAL AND
methodThis prospective observational study recruited 32 patients with CTEPH undergoing elective cardiac catheterization. As we collected arterial blood samples in the catheter laboratory, SpO2 values were simultaneously recorded. Three pulse oximeters were used on each patient, and SpO2 values were compared with oximetry readings using a blood gas analyzer. To determine the optimal SpO2 value by which to detect hypoxemia (SaO2≦90%), we generated receiver operating characteristic (ROC) curves for each pulse oximeter.
resultThe root mean square of each pulse oximeter was 1.79 (OLV-3100), 1.64 (N-BS), and 2.50 (Masimo Radical). The mean bias (SpO2 - SaO2) for the 90%-95% saturation range was significantly higher for Masimo Radical (0.19 +/- 1.78% [OLV-3100], 0.18 +/- 1.63% [N-BS], and 1.61 +/- 1.91% [Masimo Radical]; p<0.0001). The optimal SpO2 value to detect hypoxemia (SaO2≦90%) was 89% for OLV-3100, 90% for N-BS, and 92% for Masimo Radical.
conclusionWe found that the biases and precision with which to detect hypoxemia differed among the three pulse oximeters. To avoid hypoxemia, the optimal SpO2 should be determined for each pulse oximeter.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials