Evidence map›Paper›PMID 25975192›Full record

ArticleMagnetic resonance in medicine2015

Wideband arrhythmia-Insensitive-rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by an implantable-cardioverter-defibrillator.

KyungPyo Hong, Eun-Kee Jeong, T Scott Wall, Stavros G Drakos, Daniel Kim

Open access · bronzeAbstract readEvaluation Study
In one paragraph

Article in Magnetic resonance in medicine, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed, 1 pooled it
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 1 synthesis or guideline pooled it, 31 citations in OpenAlex.

  1. SCMR expert consensus statement for cardiovascular magnetic resonance of patients with a cardiac implantable electronic device.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2024
    Guideline
  2. Article
  3. Article
  4. Article
  5. Myocardial blood flow quantification in patients with an implanted cardiodefibrillator during stress and at rest using a wideband perfusion pulse sequence: an initial feasibility study.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025
    Article
  6. Article
  7. Review
  8. Article
  9. Motion-compensated TFrontiers in cardiovascular medicine · 2023
    Review
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Observational
  17. Article
  18. Myocardial T2 mapping using wideband T2 preparation gradient echo readout for patients with implantable cardiac devices at 1.5T.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

KyungPyo HongDepartment of Bioengineering, University of Utah, Salt Lake City, Utah, USA.
Eun-Kee JeongUCAIR, Department of Radiology, University of Utah, Salt Lake City, Utah, USA.
T Scott WallDivision of Cardiology, Internal Medicine, University of Utah, Salt Lake, Utah, USA.
Stavros G DrakosDivision of Cardiology, Internal Medicine, University of Utah, Salt Lake, Utah, USA.
Daniel KimUCAIR, Department of Radiology, University of Utah, Salt Lake City, Utah, USA.
University of Utah · USUniversity of Utah Hospital · US

Funding

Precision MRI of Left Atrial Fibrosis for Patients with Atrial FibrillationR01HL116895 · NHLBI · UNIVERSITY OF UTAH · PI KIM, DANIEL · 2014 to 2025
$5.1M
NHLBI NIH HHS R01 HL116895NHLBI NIH HHS R01HL116895-01A1
6 · The paper itself

Abstract

purposeTo develop and evaluate a wideband arrhythmia-insensitive-rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by implantable-cardioverter-defibrillator (ICD).

methodsWe developed a wideband AIR pulse sequence by incorporating a saturation pulse with wide frequency bandwidth (8.9 kHz) to achieve uniform T1 weighting in the heart with ICD. We tested the performance of original and "wideband" AIR cardiac T1 mapping pulse sequences in phantom and human experiments at 1.5 Tesla.

resultsIn five phantoms representing native myocardium and blood and postcontrast blood/tissue T1 values, compared with the control T1 values measured with an inversion-recovery pulse sequence without ICD, T1 values measured with original AIR with ICD were considerably lower (absolute percent error > 29%), whereas T1 values measured with wideband AIR with ICD were similar (absolute percent error < 5%). Similarly, in 11 human subjects, compared with the control T1 values measured with original AIR without ICD, T1 measured with original AIR with ICD was significantly lower (absolute percent error > 10.1%), whereas T1 measured with wideband AIR with ICD was similar (absolute percent error < 2.0%).

conclusionThis study demonstrates the feasibility of a wideband pulse sequence for cardiac T1 mapping without significant image artifacts induced by ICD.

Indexed as

ArtifactsDefibrillators, ImplantableSignal Processing, Computer-AssistedAdultAlgorithmsArrhythmias, CardiacFeasibility StudiesFemaleHumansImage EnhancementMagnetic Resonance ImagingMalePhantoms, ImagingReproducibility of ResultsSensitivity and Specificitycardiac T1 mappingECVheart failureICDmyocardial fibrosissudden cardiac deathwideband

Identifiers

PMID25975192
PMCPMC4515197
OpenAlexW2146215738

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.