Evidence map›Paper›PMID 25972280›Full record

ArticleJournal of diabetes science and technology2015

Use of an Intravascular Fluorescent Continuous Glucose Sensor in ICU Patients.

Paul J Strasma, Simon Finfer, Oliver Flower, Brian Hipszer, Mikhail Kosiborod, Lewis Macken, Marjolein Sechterberger, Peter H J van der Voort, J Hans DeVries, Jeffrey I Joseph

Open access · bronzeAbstract readMulticenter Study
In one paragraph

Article in Journal of diabetes science and technology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
2.7field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 22 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Review
  4. Article
  5. Review
  6. Continuous Glucose Monitoring in the Intensive Care Unit.Journal of diabetes science and technology · 2023
    Article
  7. Article
  8. Review
  9. Review
  10. Article
  11. Article
  12. Glucose Control in the ICU: A Continuing Story.Journal of diabetes science and technology · 2016
    Review
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 7 institutions in 3 countries.

Paul J StrasmaGluMetrics, Inc, Irvine, CA, USA paul.strasma@gmail.com.
Simon FinferRoyal North Shore Hospital, Sydney, Australia University of Sydney, Sydney, Australia.
Oliver FlowerRoyal North Shore Hospital, Sydney, Australia.
Brian HipszerThomas Jefferson University Hospital, Philadelphia, PA, USA.
Mikhail KosiborodSaint Luke's Mid America Heart Institute, University of Missouri-Kansas City, Kansas City, MO, USA.
Lewis MackenRoyal North Shore Hospital, Sydney, Australia.
Marjolein SechterbergerAcademic Medical Center, University of Amsterdam, Amsterdam, Netherlands.
Peter H J van der VoortOnze Lieve Vrouwe Gasthuis, Amsterdam, Netherlands TIAS School for Business, Tilburg, Netherlands.
J Hans DeVriesAcademic Medical Center, University of Amsterdam, Amsterdam, Netherlands.
Jeffrey I JosephThomas Jefferson University Hospital, Philadelphia, PA, USA.
Royal North Shore Hospital · AUThomas Jefferson University Hospital · USAcademic Medical Center · NLTIAS School for Business and Society · NLUniversity of Amsterdam · NLUniversity of Missouri–Kansas City · USUniversity of Sydney · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHyperglycemia and hypoglycemia are associated with adverse clinical outcomes in intensive care patients. In product development studies at 4 ICUs, the safety and performance of an intravascular continuous glucose monitoring (IV-CGM) system was evaluated in 70 postsurgical patients.

methodsThe GluCath System (GluMetrics, Inc) used a quenched chemical fluorescence mechanism to optically measure blood glucose when deployed via a radial artery catheter or directly into a peripheral vein. Periodic ultrasound assessed blood flow and thrombus formation. Patient glucose levels were managed according to the standard of care and existing protocols at each site. Reference blood samples were acquired hourly and compared against prospectively calibrated sensor results.

resultsIn all, 63 arterial sensors and 9 venous sensors were deployed in 70 patients. Arterial sensors did not interfere with invasive blood pressure monitoring, sampling or other aspects of patient care. A majority of venous sensors (66%) exhibited thrombus on ultrasound. In all, 89.4% (1383/1547) of arterial and 72.2% (182/252) of venous measurements met ISO15197:2003 criteria (within 20%), and 72.7% (1124/1547) of arterial and 56.3% (142/252) of venous measurements met CLSI POCT 12-A3 criteria (within 12.5%). The aggregate mean absolute relative difference (MARD) between the sensors and the reference was 9.6% for arterial and 14.2% for venous sensors.

conclusionsThe GluCath System exhibited acceptable accuracy when deployed in a radial artery for up to 48 hours in ICU patients after elective cardiac surgery. Accuracy of venous deployment was substantially lower with significant rates of intravascular thrombus observed using ultrasound.

Indexed as

Critical CareInsulin Infusion SystemsAgedBlood GlucoseCardiac Surgical ProceduresCohort StudiesDiabetes MellitusFemaleHumansHyperglycemiaHypoglycemiaInfusions, IntravenousIntensive Care UnitsMaleMiddle AgedMonitoring, PhysiologicBlood Glucosecontinuous glucose monitoringhospitalintensive careintravascular

Identifiers

PMID25972280
PMCPMC4525661
OpenAlexW2120226132

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.