ArticleEuropean journal of nuclear medicine and molecular imaging2015
A multicentre comparison of quantitative (90)Y PET/CT for dosimetric purposes after radioembolization with resin microspheres : The QUEST Phantom Study.
Article in European journal of nuclear medicine and molecular imaging, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 71 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
71 citing papers in PubMed.
- Holmium-166 radioembolisation dosimetry in HCC.European journal of nuclear medicine and molecular imaging · 2025Trial
- A comparison of methods for in vivo activity and absorbed dose quantification with PET/CT following yttrium-90 radioembolization.Medical physics · 2024Trial
- Effects of dose heterogeneity on response and toxicity afterEuropean journal of nuclear medicine and molecular imaging · 2026Article
- Optimising [Formula: see text] PET imaging for dosimetry in SIRT: insights from phantom and simulation studies on the Discovery MI scanner.EJNMMI physics · 2026Article
- Impact of scan duration and scatter correction on quantitative accuracy in Yttrium-90 PET/CT imaging using LAFOV and SAFOV systems: a phantom and clinical evaluation.EJNMMI physics · 2026Article
- Multimodal imaging techniques in Yttrium-90 radioembolization for hepatocellular carcinoma: a modality-oriented clinical review.Frontiers in oncology · 2026Review
- Tumor Burden Thresholds Associated with Successful Downstaging After Yttrium-90 Radioembolization in Hepatocellular Carcinoma Beyond UCSF Criteria.Journal of hepatocellular carcinoma · 2026Article
- Recommendations for Standardizing Nuclear Medicine Terminology and Data in the Era of Theranostics and Artificial Intelligence.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2025Article
- Evaluation of long axial field-of-view (LAFOV) PET/CT for post-treatment dosimetry in Yttrium-90 radioembolization of liver tumors: a comparative study with conventional SPECT imaging.European journal of nuclear medicine and molecular imaging · 2025Article
- Do we need dosimetry for the optimization of theranostics in CNS tumors?Neuro-oncology · 2024Review
- Quantitative evaluation ofMedical physics · 2024Article
- Article
- EANM guidance document: dosimetry for first-in-human studies and early phase clinical trials.European journal of nuclear medicine and molecular imaging · 2024Article
- Article
- The Importance of Uncertainty Analysis and Traceable Measurements in Routine QuantitativePharmaceuticals (Basel, Switzerland) · 2023Article
- Characterization of the partial volume effect along the axial field-of-view of the Biograph Vision Quadra total-body PET/CT system for multiple isotopes.EJNMMI physics · 2023Article
- Triple modality image reconstruction of PET data using SPECT, PET, CT information increases lesion uptake in images of patients treated with radioembolization withEJNMMI physics · 2023Article
- A Multicenter Study on Observed Discrepancies Between Vendor-Stated and PET-MeasuredJournal of nuclear medicine : official publication, Society of Nuclear Medicine · 2023Article
- Lesion Quantification Accuracy of DigitalJournal of nuclear medicine : official publication, Society of Nuclear Medicine · 2023Article
- Towards personalised dosimetry in patients with liver malignancy treated withEJNMMI physics · 2022Article
11 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
purposeTo investigate and compare the quantitative accuracy of (90)Y imaging across different generation PET/CT scanners, for the purpose of dosimetry after radioembolization with resin microspheres.
methodsA strict experimental and imaging protocol was followed by 47 international sites using the NEMA 2007/IEC 2008 PET body phantom with an 8-to-1 sphere-to-background ratio of (90)Y solution. The phantom was imaged over a 7-day period (activity ranging from 0.5 to 3.0 GBq) and all reconstructed data were analysed at a core laboratory for consistent processing. Quantitative accuracy was assessed through measures of total phantom activity, activity concentration in background and hot spheres, misplaced counts in a nonradioactive insert, and background variability.
resultsOf the 69 scanners assessed, 37 had both time-of-flight (ToF) and resolution recovery (RR) capability. These current generation scanners from GE, Philips and Siemens could reconstruct background concentration measures to within 10% of true values over the evaluated range, with greater deviations on the Philips systems at low count rates, and demonstrated typical partial volume effects on hot sphere recovery, which dominated spheres of diameter <20 mm. For spheres >20 mm in diameter, activity concentrations were consistently underestimated by about 20%. Non-ToF scanners from GE Healthcare and Siemens were capable of producing accurate measures, but with inferior quantitative recovery compared with ToF systems.
conclusionCurrent generation ToF scanners can consistently reconstruct (90)Y activity concentrations, but they underestimate activity concentrations in small structures (≤37 mm diameter) within a warm background due to partial volume effects and constraints of the reconstruction algorithm. At the highest count rates investigated, measures of background concentration (about 300 kBq/ml) could be estimated on average to within 1%, 5% and 2% for GE Healthcare (all-pass filter, RR + ToF), Philips (4i8s ToF) and Siemens (2i21s all-pass filter, RR + ToF) ToF systems, respectively. Over the range of activities investigated, comparable performance between GE Healthcare and Siemens ToF systems suggests suitability for quantitative analysis in a scenario analogous to that of postradioembolization imaging for treatment of liver cancer.