Evidence map›Paper›PMID 25961508›Full record

ArticleNature nanotechnology2015

High-efficiency resonant amplification of weak magnetic fields for single spin magnetometry at room temperature.

Luka Trifunovic, Fabio L Pedrocchi, Silas Hoffman, Patrick Maletinsky, Amir Yacoby, Daniel Loss

Abstract read
PubMed Publisher
In one paragraph

Article in Nature nanotechnology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. A quantum spin-probe molecular microscope.Nature communications · 2016
    Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Luka TrifunovicDepartment of Physics, University of Basel, Klingelbergstrasse 82, Basel CH-4056, Switzerland.
Fabio L Pedrocchi1] Department of Physics, University of Basel, Klingelbergstrasse 82, Basel CH-4056, Switzerland [2] JARA Institute for Quantum Information, RWTH Aachen University, Aachen D-52056, Germany.
Silas HoffmanDepartment of Physics, University of Basel, Klingelbergstrasse 82, Basel CH-4056, Switzerland.
Patrick MaletinskyDepartment of Physics, University of Basel, Klingelbergstrasse 82, Basel CH-4056, Switzerland.
Amir Yacoby1] Department of Physics, Harvard University, Cambridge Massachusetts 02138, USA [2] Condensed Matter Chair, Department of Physics and Astronomy, University of Waterloo, Canada.
Daniel LossDepartment of Physics, University of Basel, Klingelbergstrasse 82, Basel CH-4056, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Magnetic resonance techniques not only provide powerful imaging tools that have revolutionized medicine, but they have a wide spectrum of applications in other fields of science such as biology, chemistry, neuroscience and physics. However, current state-of-the-art magnetometers are unable to detect a single nuclear spin unless the tip-to-sample separation is made sufficiently small. Here, we demonstrate theoretically that by placing a ferromagnetic particle between a nitrogen-vacancy magnetometer and a target spin, the magnetometer sensitivity is improved dramatically. Using materials and techniques that are already experimentally available, our proposed set-up is sensitive enough to detect a single nuclear spin within ten milliseconds of data acquisition at room temperature. The sensitivity is practically unchanged when the ferromagnet surface to the target spin separation is smaller than the ferromagnet lateral dimensions; typically about a tenth of a micrometre. This scheme further benefits when used for nitrogen-vacancy ensemble measurements, enhancing sensitivity by an additional three orders of magnitude.

Indexed as

Magnetic FieldsMagnetsAmplifiers, ElectronicEquipment DesignEquipment Failure AnalysisMagnetite NanoparticlesMagnetometryMicro-Electrical-Mechanical SystemsNanotechnologyReproducibility of ResultsSensitivity and SpecificitySpin LabelsMagnetite NanoparticlesSpin Labels

Identifiers

PMID25961508

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.