Evidence map›Paper›PMID 25961285›Full record

ArticlePloS one2015

Numerical Modeling of Intraventricular Flow during Diastole after Implantation of BMHV.

Boyang Su, Foad Kabinejadian, Hui Qun Phang, Gideon Praveen Kumar, Fangsen Cui, Sangho Kim, Ru San Tan, Jimmy Kim Fatt Hon, John Carson Allen, Hwa Liang Leo and 1 more

Abstract read
In one paragraph

Article in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Intracardiac flow dynamics in mitral regurgitation: state of the art.European heart journal. Imaging methods and practice · 2025
    Review
  2. Article
  3. Article
  4. Review
  5. Review
  6. Heart blood flow simulation: a perspective review.Biomedical engineering online · 2016
    Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Boyang SuNational Heart Research Institute of Singapore, National Heart Centre Singapore, Singapore, Singapore.
Foad KabinejadianDepartment of Biomedical Engineering, National University of Singapore, Singapore, Singapore.
Hui Qun PhangDepartment of Surgery, National University of Singapore, Singapore, Singapore.
Gideon Praveen KumarInstitute of High Performance Computing, ASTAR, Singapore, Singapore.
Fangsen CuiInstitute of High Performance Computing, ASTAR, Singapore, Singapore.
Sangho KimDepartment of Biomedical Engineering, National University of Singapore, Singapore, Singapore.
Ru San TanNational Heart Research Institute of Singapore, National Heart Centre Singapore, Singapore, Singapore.
Jimmy Kim Fatt HonDepartment of Surgery, National University of Singapore, Singapore, Singapore.
John Carson AllenDuke-NUS Graduate Medical School, Singapore, Singapore.
Hwa Liang LeoDepartment of Biomedical Engineering, National University of Singapore, Singapore, Singapore.
Liang ZhongNational Heart Research Institute of Singapore, National Heart Centre Singapore, Singapore, Singapore; Duke-NUS Graduate Medical School, Singapore, Singapore.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This work presents a numerical simulation of intraventricular flow after the implantation of a bileaflet mechanical heart valve at the mitral position. The left ventricle was simplified conceptually as a truncated prolate spheroid and its motion was prescribed based on that of a healthy subject. The rigid leaflet rotation was driven by the transmitral flow and hence the leaflet dynamics were solved using fluid-structure interaction approach. The simulation results showed that the bileaflet mechanical heart valve at the mitral position behaved similarly to that at the aortic position. Sudden area expansion near the aortic root initiated a clockwise anterior vortex, and the continuous injection of flow through the orifice resulted in further growth of the anterior vortex during diastole, which dominated the intraventricular flow. This flow feature is beneficial to preserving the flow momentum and redirecting the blood flow towards the aortic valve. To the best of our knowledge, this is the first attempt to numerically model intraventricular flow with the mechanical heart valve incorporated at the mitral position using a fluid-structure interaction approach. This study facilitates future patient-specific studies.

Indexed as

DiastoleHeart Valve ProsthesisHeart VentriclesHemodynamicsModels, CardiovascularVentricular FunctionAlgorithmsBlood Flow VelocityComputer SimulationHeart Valve Prosthesis ImplantationHumansVentricular Pressure

Identifiers

PMID25961285
PMCPMC4427484

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.