Evidence map›Paper›PMID 25957590›Full record

ArticleInternational orthopaedics2016

Fluoroscopy assessment during anterior minimally invasive hip replacement is more accurate than with the posterior approach.

Weifeng Ji, Nathaniel Stewart

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in International orthopaedics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed, 1 pooled it
3.2field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed, 1 synthesis or guideline pooled it, 39 citations in OpenAlex.

  1. Radiation exposure in fluoroscopy-guided anterior total hip arthroplasty: a systematic review.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2022
    Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 2 countries.

Weifeng JiDepartment of Orthopaedics, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China. jiweifeng1230@163.com.
Nathaniel StewartDepartment of Orthopaedics, Chippewa Valley Orthopaedics and Sports Medicine Clinic, Altoona, WI, USA.
Chippewa Valley Technical College · USZhejiang Chinese Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeAcetabular component position is important for stability and wear. Fluoroscopy can improve the accuracy of acetabular component placement in the posterior approach and the direct anterior approach (DAA). The purpose of this study was to determine if the direct anterior approach in the supine position facilitates the accurate use of fluoroscopy and improves acetabular component position.

methodsThis retrospective, comparative study of 60 THAs with fluoroscopic guidance (30 in posterior approach group and 30 in DAA group) was performed by one surgeon from 2012 to 2014 at a single institution. Demographic and perioperative data were compared using the Kolmogorov-Smirnov test to determine if they were statistically different. The difference between the measured intra-operative and postoperative values for both inclination and anteversion were analysed respectively.

resultsIn the posterior approach group we found an average inclination on intra-operative fluoroscopy (IFluoro) of 36.8° ± 3.72°, an average anteversion on intra-operative fluoroscopy (AFluoro) of 25.6° ± 3.64°, an average inclination on postoperative standing AP pelvis X-ray (IAP X-ray) of 39.29° ± 4.58° and an average anteversion on postoperative standing AP pelvis X-ray (AAP X-ray) of 21.31° ± 4.04°. In the DAA group we found an average DAA IFluoro of 42.32° ± 1.91°, an average DAA AFluoro of 22.3° ± 1.41°, an average DAA IAP X-ray of 42.98° ± 1.81° and an average DAA AAP X-ray of 22.88° ± 1.38°. A difference was seen in variability using Kolmogorov-Smirnov test for inclination and anteversion with significant higher variation of measurements in the posterior approach group (p = 0.022 and p < 0.001 respectively). No statistically significant difference was seen in the DAA group using the fluoroscopy for inclination and anteversion.

conclusionUsing fluoroscopy in the direct anterior approach, we achieved better intra-operative assessment of cup orientation resulting in decreased variability of acetabular cup anteversion than when used in the posterior approach. At least some of the improvement was due to the fact that the fluoroscopic image in the supine position was more accurate as measured against the postoperative standing AP pelvis. This study may influence the choice of approach in total hip replacement.

Indexed as

Arthroplasty, Replacement, HipFluoroscopyHip JointHip ProsthesisHumansMaleMiddle AgedMinimally Invasive Surgical ProceduresPatient PositioningRetrospective StudiesAcetabular componentAnteversionDirect anterior approach (DAA)FluoroscopyInclinationPosterior approach

Identifiers

PMID25957590
OpenAlexW768881589

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.