ArticleIEEE transactions on medical imaging2015
Temporal Sparse Promoting Three Dimensional Imaging of Cardiac Activation.
Article in IEEE transactions on medical imaging, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Trial
- Volumetric non-invasive cardiac mapping for accessible global arrhythmia characterization.Communications medicine · 2026Article
- Toward Enabling Cardiac Digital Twins of Myocardial Infarction Using Deep Computational Models for Inverse Inference.IEEE transactions on medical imaging · 2024Article
- ECG Localization Method Based on Volume Conductor Model and Kalman Filtering.Sensors (Basel, Switzerland) · 2021Article
- Noninvasive Imaging of Epicardial and Endocardial Potentials With Low Rank and Sparsity Constraints.IEEE transactions on bio-medical engineering · 2019Article
- Noninvasive Activation Imaging of Ventricular Arrhythmias by Spatial Gradient Sparse in Frequency Domain-Application to Mapping Reentrant Ventricular Tachycardia.IEEE transactions on medical imaging · 2019Article
- Wavelet-promoted sparsity for non-invasive reconstruction of electrical activity of the heart.Medical & biological engineering & computing · 2018Article
- Three-Dimensional Noninvasive Imaging of Ventricular Arrhythmias in Patients With Premature Ventricular Contractions.IEEE transactions on bio-medical engineering · 2018Article
- Localization of Origins of Premature Ventricular Contraction by Means of Convolutional Neural Network From 12-Lead ECG.IEEE transactions on bio-medical engineering · 2018Article
- Noninvasive Imaging of Human Atrial Activation during Atrial Flutter and Normal Rhythm from Body Surface Potential Maps.PloS one · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
A new Cardiac Electrical Sparse Imaging (CESI) technique is proposed to image cardiac activation throughout the three-dimensional myocardium from body surface electrocardiogram (ECG) with the aid of individualized heart-torso geometry. The sparse property of cardiac electrical activity in the time domain is utilized in the temporal sparse promoting inverse solution, one formulated to achieve higher spatial-temporal resolution, stronger robustness and thus enhanced capability in imaging cardiac electrical activity. Computer simulations were carried out to evaluate the performance of this imaging method under various circumstances. A total of 12 single site pacing and 7 dual sites pacing simulations with artificial and the hospital recorded sensor noise were used to evaluate the accuracy and stability of the proposed method. Simulations with modeling error on heart-torso geometry and electrode-torso registration were also performed to evaluate the robustness of the technique. In addition to the computer simulations, the CESI algorithm was further evaluated using experimental data in an animal model where the noninvasively imaged activation sequences were compared with those measured with simultaneous intracardiac mapping. All of the CESI results were compared with conventional weighted minimum norm solutions. The present results show that CESI can image with better accuracy, stability and stronger robustness in both simulated and experimental circumstances. In sum, we have proposed a novel method for cardiac activation imaging, and our results suggest that the CESI has enhanced performance, and offers the potential to image the cardiac activation and to assist in the clinical management of ventricular arrhythmias.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.