Evidence map›Paper›PMID 25955585›Full record

ArticleIEEE transactions on medical imaging2015

Noise Suppression for Dual-Energy CT Through Entropy Minimization.

Michael Petrongolo, Lei Zhu

Erratum issuedAbstract read
In one paragraph

Article in IEEE transactions on medical imaging, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Trial
  2. Article
  3. [Electroencephalogram signals decomposition based on improved variational mode decomposition for depression recognition].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2026
    Article
  4. Article
  5. Article
  6. Multi-Material Decomposition Using Spectral Diffusion Posterior Sampling.IEEE transactions on bio-medical engineering · 2025
    Article
  7. Review
  8. Article
  9. Article
  10. Image-domain Material Decomposition for Spectral CT using a Generalized Dictionary Learning.IEEE transactions on radiation and plasma medical sciences · 2021
    Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

2 authors.

Michael Petrongolo
Lei Zhu

Funding

Scatter Correction for Cone-Beam CT to Improve Radiation Therapy TreatmentsR21EB012700 · NIBIB · GEORGIA INSTITUTE OF TECHNOLOGY · PI ZHU, LEI · 2011 to 2012
$467k
NIBIB NIH HHS R21 EB012700
6 · The paper itself

Abstract

In dual energy CT (DECT), noise amplification during signal decomposition significantly limits the utility of basis material images. Since clinically relevant objects typically contain a limited number of different materials, we propose an Image-domain Decomposition method through Entropy Minimization (IDEM) for noise suppression in DECT. Pixels of decomposed images are first linearly transformed into 2D clusters of data points, which are highly asymmetric due to strong signal correlation. An optimal axis is identified in the 2D space via numerical search such that the projection of data clusters onto the axis has minimum entropy. Noise suppression is performed on each image pixel by estimating the center-of-mass value of each data cluster along the direction perpendicular to the projection axis. The IDEM method is distinct from other noise suppression techniques in that it does not suppress pixel noise by reducing spatial variation between neighboring pixels. As supported by studies on Catphan©600 and anthropomorphic head phantoms, this feature endows our algorithm with a unique capability of reducing noise standard deviation on DECT decomposed images by approximately one order of magnitude while preserving spatial resolution and image noise power spectra (NPS). Compared with a filtering method and recently developed iterative method at the same level of noise suppression, the IDEM algorithm obtains high-resolution images with less artifacts. It also maintains accuracy of electron density measurements with less than 2% bias error. The IDEM method effectively suppresses noise of DECT for quantitative use, with appealing features on preservation of image spatial resolution and NPS.

Indexed as

EntropyHeadHumansImage Processing, Computer-AssistedModels, BiologicalPhantoms, ImagingTomography, X-Ray Computed

Identifiers

PMID25955585
PMCPMC4671518

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.