Evidence map›Paper›PMID 25948321›Full record

ArticleTechnology in cancer research & treatment2016

Adaptation, Commissioning, and Evaluation of a 3D Treatment Planning System for High-Resolution Small-Animal Irradiation.

Jeho Jeong, Qing Chen, Robert Febo, Jie Yang, Hai Pham, Jian-Ping Xiong, Pat B Zanzonico, Joseph O Deasy, John L Humm, Gig S Mageras

Abstract read
In one paragraph

Article in Technology in cancer research & treatment, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jeho JeongDepartment of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, USA.
Qing ChenDepartment of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, USA.
Robert FeboDepartment of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, USA.
Jie YangDepartment of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, USA.
Hai PhamDepartment of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, USA.
Jian-Ping XiongDepartment of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, USA.
Pat B ZanzonicoDepartment of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, USA.
Joseph O DeasyDepartment of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, USA.
John L HummDepartment of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, USA hummj@mskcc.org.
Gig S MagerasDepartment of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, USA.

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI Nicholas D Socci · 1985 to 2026
$347.4M
NCI NIH HHS P30 CA008748
6 · The paper itself

Abstract

Although spatially precise systems are now available for small-animal irradiations, there are currently limited software tools available for treatment planning for such irradiations. We report on the adaptation, commissioning, and evaluation of a 3-dimensional treatment planning system for use with a small-animal irradiation system. The 225-kV X-ray beam of the X-RAD 225Cx microirradiator (Precision X-Ray) was commissioned using both ion-chamber and radiochromic film for 10 different collimators ranging in field size from 1 mm in diameter to 40 × 40 mm(2) A clinical 3-dimensional treatment planning system (Metropolis) developed at our institution was adapted to small-animal irradiation by making it compatible with the dimensions of mice and rats, modeling the microirradiator beam orientations and collimators, and incorporating the measured beam data for dose calculation. Dose calculations in Metropolis were verified by comparison with measurements in phantoms. Treatment plans for irradiation of a tumor-bearing mouse were generated with both the Metropolis and the vendor-supplied software. The calculated beam-on times and the plan evaluation tools were compared. The dose rate at the central axis ranges from 74 to 365 cGy/min depending on the collimator size. Doses calculated with Metropolis agreed with phantom measurements within 3% for all collimators. The beam-on times calculated by Metropolis and the vendor-supplied software agreed within 1% at the isocenter. The modified 3-dimensional treatment planning system provides better visualization of the relationship between the X-ray beams and the small-animal anatomy as well as more complete dosimetric information on target tissues and organs at risk. It thereby enhances the potential of image-guided microirradiator systems for evaluation of dose-response relationships and for preclinical experimentation generally.

Indexed as

Models, AnimalAnimalsMiceRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedTomography, X-Ray Computed3D dose distributioncommissioningradiation therapysmall-animal irradiatortreatment planning system

Identifiers

PMID25948321
PMCPMC4823181

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.