Evidence map›Paper›PMID 25944685›Full record

Trial reportAnnals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc2016

Man versus Machine: Comparison of Automated and Manual Methodologies for Measuring the QTc Interval: A Prospective Study.

Jean T Barbey, Margaret Connolly, Brenda Beaty, Mori J Krantz

Abstract readComparative StudyRandomized Controlled Trial
In one paragraph

Trial report in Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Man versus machine? Acquired long QT syndrome in a patient with anorexia nervosa.Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jean T BarbeySocial & Scientific Systems, Inc, Silver Spring, MD.
Margaret ConnollyPAREXEL International Corp, Waltham, MA.
Brenda BeatyUniversity of Colorado, Aurora, Colorado.
Mori J KrantzDenver Health and Hospitals, Denver, CO.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundElectrocardiographic (ECG) safety evaluation is a required element of drug development. Performance characteristics of ECG measurement methodologies have rarely been studied prospectively.

methodsWe conducted a randomized, placebo-controlled, crossover study in 24 subjects to evaluate effects of moxifloxacin on the Fridericia rate-corrected QT (QTcF) interval. Five ECG replicates were obtained at 30 time points. Change from baseline QTcF (ΔQTcF) was fit by mixed-model analysis of variance to evaluate residual standard deviation. Precision was defined as intrasubject QTcF variance. Two core lab approaches were compared: QTinno, fully automated, 5 replicates and HeartSignals, computer-assisted manual, 3 replicates. Core lab values were then compared to an automated commercial algorithm (VERITAS).

resultsTwenty-three subjects provided 3450 ECGs potentially available for analysis. QTinno QTcF values were based upon 3419 ECGs, HeartSignals data on 2028 ECGs. Variance was similar between the QTinno and HeartSignals approaches (41.5 and 44 ms(2)). After excluding VERITAS QTcF measurements that deviated by >40 ms on visual review, variance in a set of 1907 common ECGs was lowest for HeartSignal, followed by QTinno and VERITAS (43.8, 52.6, 89.4 ms(2)) P = 0.02 HeartSignals versus QTinno, P < 0.0001 for both HeartSignals and QTinno versus VERITAS.

conclusionsA fully automated core lab approach using 5 replicates and a computer-assisted manual approach using 3 replicates were equally precise. When an identical number of ECGs were compared, the computer-assisted manual method was most precise, while the commercial algorithm was relatively imprecise. Although suitable for clinical assessment the standard commercial algorithm cannot be recommended for regulated safety research.

Indexed as

AlgorithmsAnti-Bacterial AgentsCross-Over StudiesDiagnosis, Computer-AssistedDose-Response Relationship, DrugElectrocardiographyFemaleFluoroquinolonesHeart Conduction SystemHumansMaleMoxifloxacinProspective StudiesSingle-Blind MethodTorsades de PointesAnti-Bacterial AgentsFluoroquinolonesMoxifloxacinautomatedECG core laboratorieselectrocardiographymanualQTc interval

Identifiers

PMID25944685
PMCPMC6931865

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.