Evidence map›Paper›PMID 25920438›Full record

ArticleLa Radiologia medica2015

Evaluation based on Monte Carlo simulation of lifetime attributable risk of cancer after neck X-ray radiography.

Deoknam Seo, Seonggyu Han, Kie Hwan Kim, Jungsu Kim, Kyung Park, Hyunjong Lim, Jungmin Kim

Abstract readMulticenter Study
PubMed Publisher
In one paragraph

Article in La Radiologia medica, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.5field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Deoknam SeoDepartment of Diagnostic Radiology, Korea Institute of Radiological and Medical Sciences, Seoul, 139-706, Republic of Korea. duck9298@korea.ac.kr.
Seonggyu HanDepartment of Bio-Convergence Engineering, Korea University Graduate School, Seoul, 136-703, Republic of Korea. goodcoat@korea.ac.kr.
Kie Hwan KimDepartment of Diagnostic Radiology, Korea Institute of Radiological and Medical Sciences, Seoul, 139-706, Republic of Korea. khkim@kirams.re.kr.
Jungsu KimDepartment of Bio-Convergence Engineering, Korea University Graduate School, Seoul, 136-703, Republic of Korea. rtkjs@korea.ac.kr.
Kyung ParkDepartment of Diagnostic Radiology, Korea Institute of Radiological and Medical Sciences, Seoul, 139-706, Republic of Korea. pk-king@hanmail.net.
Hyunjong LimDepartment of Bio-Convergence Engineering, Korea University Graduate School, Seoul, 136-703, Republic of Korea. silltown@nate.com.
Jungmin KimDepartment of Radiologic Science, College of Health Science, Korea University, Seoul, 136-703, Republic of Korea. minbogun@korea.ac.kr.
Korea University · KRKorea Institute of Radiological and Medical Sciences · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

At present, concern regarding radiation exposure is increasing with the prevalence of radiologic examination. As radiation damages the human body, we have evaluated medical radiation dose values and studied the importance of optimizing radiation exposure. We measured entrance surface dose (ESD) values using a RANDO(®) phantom (neck) in 94 randomly selected locations in the central region of Korea. Thyroid and organ doses were calculated using Monte Carlo simulations (PCXMC 2.0.1) based on measured values. In addition, the lifetime attributable risk (LAR) of cancer was calculated for the thyroid, using the method proposed in the biological effects of ionizing radiation VII report. The average measured ESD values obtained using the RANDO(®) phantom (neck) were antero-posterior 1.33 mGy and lateral 1.23 mGy, for a total of 2.56 mGy. Based on the ESD values measured using the phantom, the organ doses were obtained using a Monte Carlo simulation (PCXMC 2.0.1). The thyroid dose was 1.48 mSv on average. In evaluating the LAR of thyroid cancer incidence, a frequency of 0.02 per 100,000 from 2.94 per 100,000 males and a frequency of 0.10 per 100,000 from 16.23 per 100,000 females were found. The risk of cancer was found to be higher when the patient's age was lower, and was also higher in females than in males. It was concluded that beneficial exams in the medical field should not be prohibited because of a statistically small risk, although acknowledgement of the dangers of ionizing radiation is necessary.

Indexed as

FemaleHumansIncidenceMaleMonte Carlo MethodNeckNeoplasms, Radiation-InducedPhantoms, ImagingRadiation DosageRadiometryRepublic of KoreaRisk AssessmentRisk FactorsThyroid NeoplasmsEntrance surface dose (ESD)Lifetime attributable risk (LAR)Monte Carlo simulationOrgan dosesPCXMC

Identifiers

PMID25920438
OpenAlexW2004177022

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.