Evidence map›Paper›PMID 25914524›Full record

ArticlePatient preference and adherence2015

The effects of differential injection sites of cold saline on transpulmonary thermodilution parameter values.

Wanjie Yang, Qingguo Feng, Youzhong An, Xuefeng Zhao, Kai Wei, Chang Li, Wei Wang, Hongyun Teng

Abstract read
In one paragraph

Article in Patient preference and adherence, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Wanjie YangDepartment of Critical Care, The Fifth Central Hospital of Tianjin, Tianjin, People's Republic of China.
Qingguo FengDepartment of Critical Care, The Fifth Central Hospital of Tianjin, Tianjin, People's Republic of China.
Youzhong AnDepartment of Critical Care, The People's Hospital, Peking University, Beijing, People's Republic of China.
Xuefeng ZhaoDepartment of Critical Care, The Fifth Central Hospital of Tianjin, Tianjin, People's Republic of China.
Kai WeiDepartment of Critical Care, The Fifth Central Hospital of Tianjin, Tianjin, People's Republic of China.
Chang LiDepartment of Critical Care, The Fifth Central Hospital of Tianjin, Tianjin, People's Republic of China.
Wei WangDepartment of Critical Care, The Fifth Central Hospital of Tianjin, Tianjin, People's Republic of China.
Hongyun TengDepartment of Critical Care, The Fifth Central Hospital of Tianjin, Tianjin, People's Republic of China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimTo investigate the effects of differential sites for cold saline injection on transpulmonary thermodilution parameter values.

methodsThis was a prospective study. Twelve patients were recruited for the following examinations: control condition (injection site at proximal injection end of the Swan-Ganz catheter), proximal end condition (injection site at sheath of the Swan-Ganz catheter), and distal end condition (injection site at PA end of the Swan-Ganz catheter). Sixty measurements were performed for each condition. The cardiac index, global end diastolic volume index (GEDI), and extravascular lung water index for the three different injection sites were recorded from each patient. In addition, the mean transmission time (MTt), downslope time, and area under the curve obtained from PiCCO-VoLEF-Win software were compared among different groups.

resultsThere were no differences in cardiac index and extravascular lung water index values among the three conditions (P>0.05). There were no differences in GEDI between the proximal end condition and control condition (P>0.05), while the GEDI was significantly lower for the distal end condition (493.33±254.65 mL/m(2)) than for the control condition (645.53±234.46 mL/m(2)) (P<0.05) and proximal end condition (717.96±321.63 mL/m(2)) (P<0.01). There were no differences in downslope time and area under the curve among the three conditions (P>0.05). There were no differences in MTt between the proximal end condition and control condition (P>0.05), while the MTt was significantly lower for distal end condition (40.22±16.37 seconds) than for the control condition (42.91±17.93 seconds) (P<0.05) and proximal end condition (47.16±16.64 seconds) (P<0.01).

conclusionThe differential sites for cold saline injection impacted transpulmonary thermodilution parameter values.

Indexed as

extravascular lung water indexglobal end diastolic volume indexpulmonary artery catheter

Identifiers

PMID25914524
PMCPMC4399515

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.