Evidence map›Paper›PMID 25914509›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2015

Imaging tooth enamel using zero echo time (ZTE) magnetic resonance imaging.

Kevin M Rychert, Gang Zhu, Maciej M Kmiec, Venkata K Nemani, Benjamin B Williams, Ann Barry Flood, Harold M Swartz, Barjor Gimi

Open access · greenAbstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Kevin M RychertDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755.
Gang ZhuMRI Division, Bruker BioSpin Corporation, 15 Fortune Drive, Billerica, MA 01821.
Maciej M KmiecDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755.
Venkata K NemaniDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755.
Benjamin B WilliamsDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755.
Ann Barry FloodDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755.
Harold M SwartzDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755.
Barjor GimiDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755.
Dartmouth College · USBruker (United States) · US

Funding

Translational Engineering in Cancer (TEC)P30CA023108 · NCI · DARTMOUTH COLLEGE · PI Steven D Leach · 1985 to 2026
$91.3M
Scientific and Administrative Core: Dartmouth Medical SchoolU19AI091173 · NIAID · DARTMOUTH COLLEGE · PI SWARTS, STEVEN GREGORY · 2010 to 2014
$16.3M
NCI NIH HHS P30 CA023108NIAID NIH HHS U19 AI091173
6 · The paper itself

Abstract

In an event where many thousands of people may have been exposed to levels of radiation that are sufficient to cause the acute radiation syndrome, we need technology that can estimate the absorbed dose on an individual basis for triage and meaningful medical decision making. Such dose estimates may be achieved using in vivo electron paramagnetic resonance (EPR) tooth biodosimetry, which measures the number of persistent free radicals that are generated in tooth enamel following irradiation. However, the accuracy of dose estimates may be impacted by individual variations in teeth, especially the amount and distribution of enamel in the inhomogeneous sensitive volume of the resonator used to detect the radicals. In order to study the relationship between interpersonal variations in enamel and EPR-based dose estimates, it is desirable to estimate these parameters nondestructively and without adding radiation to the teeth. Magnetic Resonance Imaging (MRI) is capable of acquiring structural and biochemical information without imparting additional radiation, which may be beneficial for many EPR dosimetry studies. However, the extremely short T2 relaxation time in tooth structures precludes tooth imaging using conventional MRI methods. Therefore, we used zero echo time (ZTE) MRI to image teeth ex vivo to assess enamel volumes and spatial distributions. Using these data in combination with the data on the distribution of the transverse radio frequency magnetic field from electromagnetic simulations, we then can identify possible sources of variations in radiation-induced signals detectable by EPR. Unlike conventional MRI, ZTE applies spatial encoding gradients during the RF excitation pulse, thereby facilitating signal acquisition almost immediately after excitation, minimizing signal loss from short T2 relaxation times. ZTE successfully provided volumetric measures of tooth enamel that may be related to variations that impact EPR dosimetry and facilitate the development of analytical procedures for individual dose estimates.

Indexed as

BiodosimetryEPRHFSSMRISegmentationZTE

Identifiers

PMID25914509
PMCPMC4405678
OpenAlexW1989112839

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.