Evidence map›Paper›PMID 25910779›Full record

ArticleClinical orthopaedics and related research2015

Acetate templating on digital images is more accurate than computer-based templating for total hip arthroplasty.

Robert Petretta, Jason Strelzow, Nicholas E Ohly, Peter Misur, Bassam A Masri

Abstract readClinical StudyComparative Study
In one paragraph

Article in Clinical orthopaedics and related research, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers.

0numbers the graph read from it
0cells of the map it votes in
28citing papers in PubMed
4.1field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

28 citing papers in PubMed, 61 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Observational
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Robert PetrettaDepartment of Orthopaedics, University of British Columbia, 3114-910 W10th Avenue, Vancouver, BC, V5Z 1M9, Canada.
Jason StrelzowDepartment of Orthopaedics, University of British Columbia, 3114-910 W10th Avenue, Vancouver, BC, V5Z 1M9, Canada.
Nicholas E OhlyDepartment of Orthopaedics, University of British Columbia, 3114-910 W10th Avenue, Vancouver, BC, V5Z 1M9, Canada.
Peter MisurDepartment of Orthopaedics, University of British Columbia, 3114-910 W10th Avenue, Vancouver, BC, V5Z 1M9, Canada.
Bassam A MasriDepartment of Orthopaedics, University of British Columbia, 3114-910 W10th Avenue, Vancouver, BC, V5Z 1M9, Canada. bas.masri@vch.ca.
University of British Columbia · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTemplating is an important aspect of preoperative planning for total hip arthroplasty and can help determine the size and positioning of the prosthesis. Historically, templating has been performed using acetate templates over printed radiographs. As a result of the increasing use of digital imaging, surgeons now either obtain additional printed radiographs solely for templating purposes or use specialized digital templating software, both of which carry additional cost. QUESTIONS/PURPOSES: The purposes of this study was to compare acetate templating of digitally calibrated images on an LCD monitor to digital templating in terms of (1) accuracy; (2) reproducibility; and (3) time efficiency.

methodsAcetate onlay templating was performed directly over digital radiographs on an LCD monitor and was compared with digital templating. Five separate observers participated in this study templating on 52 total hip arthroplasties. For the acetate templating, the digital images were magnified to the scaled reference on the templates provided by the manufacturer (ratio 1.2:1) before templating using a 25-mm marker as a reference. Both the acetate and digital templating results were then compared with the actual implanted components to determine accuracy. Interobserver and intraobserver variability was determined by an intraclass correlation coefficient. Observers recorded time to complete templating from the time of complete upload of patients' imaging onto the system to completion of templating.

resultsBoth acetate and digital templates demonstrated moderate accuracy in predicting within one size of the eventual implanted acetabular cup (77% [199 of 260]; 70% [181 of 260], respectively; p = 0.050; 95% confidence interval [CI], 0.058-0.32), whereas acetate templating was better at predicting the femoral stem compared to digital templating (75% [195 of 260]; 60% [155 of 260], respectively; p < 0.001; 95% CI, 0.084-0.32). Acetate templating showed moderate to substantial interobserver agreement (cup intraclass correlation coefficient [ICC] = 0.55; 95% CI, 0.14-0.86; femoral ICC = 0.75; 95% CI, 0.39-0.95) and both methods showed almost perfect intraobserver agreement in reproducibility (acetate cup ICC = 0.82; 95% CI, 0.66-0.97; acetate femoral ICC = 0.86; 95% CI, 0.74-0.97; digital cup ICC = 0.82; 95% CI, 0.68-0.97; digital femoral ICC = 0.88; 95% CI, 0.77-1.0). Acetate templating could be performed more quickly (acetate mean 119 seconds; range, 37-220 seconds versus 154 seconds; range, 73-343 seconds; p < 0.001).

conclusionsAcetate onlay templating on digitally calibrated images can be a reliable substitute for digital templating using specialized software. It is quicker to perform and much less expensive. Hospitals and practices need not purchase expensive software, particularly at lower volume centers. LEVEL OF EVIDENCE: Level III, diagnostic study.

Indexed as

AcetatesComputer-Aided DesignHip ProsthesisProsthesis DesignSoftwareAnatomic LandmarksArthroplasty, Replacement, HipCost-Benefit AnalysisEfficiencyHealth Care CostsHip JointHumansObserver VariationOsteoarthritis, HipPredictive Value of TestsProspective StudiesAcetates

Identifiers

PMID25910779
PMCPMC4626475
OpenAlexW1993120258

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.