Evidence map›Paper›PMID 25904741›Full record

ArticleScience translational medicine2015

An implantable microdevice to perform high-throughput in vivo drug sensitivity testing in tumors.

Oliver Jonas, Heather M Landry, Jason E Fuller, John T Santini, Jose Baselga, Robert I Tepper, Michael J Cima, Robert Langer

Erratum issued Registry-linked trialAbstract read
In one paragraph

Article in Science translational medicine, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. It is linked to trial NCT07352566 (Utilization of a Cutaneous Therapy In Situ Microdevice), which is not on this map. Cited by 96 papers.

0numbers the graph read from it
0cells of the map it votes in
96citing papers in PubMed
12.2field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07352566 phase4not yet recruitingnot on this mapstarted 2026, after this paper: background citation

Utilization of a Cutaneous Therapy In Situ Microdevice

TypeinterventionalSponsorUniversity of California, San FranciscoRan2026 to 2030Enrolled10ConditionsPsoriasis, Atopic DermatitisArmsIn situ cutaneous microdevice, Triamcinolone, 5-Fluorouracil, Calcipotriene, Tapinarof
3 · Its place in the literature

Who cites it

96 citing papers in PubMed, 187 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. APL bioengineering · 2024
    Article
  15. Engineering Heterogeneous Tumor Models for Biomedical Applications.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Review
  16. Review
  17. Article
  18. Review
  19. Article
  20. Article

36 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Oliver JonasThe David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
Heather M LandryThe David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
Jason E FullerThe David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA. Kibur Medical Inc., 29 Newbury Street, Suite 301, Boston, MA 02116, USA.
John T SantiniKibur Medical Inc., 29 Newbury Street, Suite 301, Boston, MA 02116, USA.
Jose BaselgaMemorial Sloan Kettering Cancer Center, New York, NY 10065, USA.
Robert I TepperKibur Medical Inc., 29 Newbury Street, Suite 301, Boston, MA 02116, USA. Third Rock Ventures LLC, 29 Newbury Street, Boston, MA 02116, USA.
Michael J CimaThe David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA. Department of Materials Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
Robert LangerThe David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA. Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA. rlanger@mit.edu.
Massachusetts Institute of Technology · USMemorial Sloan Kettering Cancer Center · US

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI Nicholas D Socci · 1985 to 2026
$347.4M
TRD 3 - Enabling Technologies for Intraprocedural GuidanceP41EB028741 · NIBIB · BRIGHAM AND WOMEN'S HOSPITAL · PI Carl-Fredrik Westin · 2021 to 2026
$10.7M
Implantable device for high-throughput in vivo drug sensitivity testingR21CA177391 · NCI · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI CIMA, MICHAEL J · 2014 to 2016
$647k
NCI NIH HHS P30 CA008748NCI NIH HHS R21 CA177391NCI NIH HHS R21-CA177391NIBIB NIH HHS P41 EB028741
6 · The paper itself

Abstract

Current anticancer chemotherapy relies on a limited set of in vitro or indirect prognostic markers of tumor response to available drugs. A more accurate analysis of drug sensitivity would involve studying tumor response in vivo. To this end, we have developed an implantable device that can perform drug sensitivity testing of several anticancer agents simultaneously inside the living tumor. The device contained reservoirs that released microdoses of single agents or drug combinations into spatially distinct regions of the tumor. The local drug concentrations were chosen to be representative of concentrations achieved during systemic treatment. Local efficacy and drug concentration profiles were evaluated for each drug or drug combination on the device, and the local efficacy was confirmed to be a predictor of systemic efficacy in vivo for multiple drugs and tumor models. Currently, up to 16 individual drugs or combinations can be assessed independently, without systemic drug exposure, through minimally invasive biopsy of a small region of a single tumor. This assay takes into consideration physiologic effects that contribute to drug response by allowing drugs to interact with the living tumor in its native microenvironment. Because these effects are crucial to predicting drug response, we envision that these devices will help identify optimal drug therapy before systemic treatment is initiated and could improve drug response prediction beyond the biomarkers and in vitro and ex vivo studies used today. These devices may also be used in clinical drug development to safely gather efficacy data on new compounds before pharmacological optimization.

Indexed as

AnimalsAntineoplastic AgentsApoptosisBiomarkers, TumorBiopsyCalibrationCell Line, TumorDose-Response Relationship, DrugDoxorubicinDrug Delivery SystemsDrug MonitoringDrug Screening Assays, AntitumorHumansMiceNeoplasmsPolyethylene GlycolsAntineoplastic AgentsBiomarkers, TumorDoxorubicinPolyethylene GlycolsPolymers

Identifiers

PMID25904741
PMCPMC4825177
OpenAlexW2161687028

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.