Evidence map›Paper›PMID 25901258›Full record

ArticleIranian journal of radiology : a quarterly journal published by the Iranian Radiological Society2015

Sensitivity of susceptibility-weighted imaging in detecting superparamagnetic iron oxide-labeled mesenchymal stem cells: a comparative study.

Serah Park, Byung Kook Kwak, Jisung Jung

Open access · hybridAbstract read
In one paragraph

Article in Iranian journal of radiology : a quarterly journal published by the Iranian Radiological Society, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Serah ParkDepartment of Radiology, Chung-Ang University College of Medicine, Seoul, Korea.
Byung Kook KwakDepartment of Radiology, Chung-Ang University College of Medicine, Seoul, Korea ; Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea.
Jisung JungDepartment of Radiology, Chung-Ang University College of Medicine, Seoul, Korea.
Chung-Ang University · KRChung-Ang University Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSusceptibility-weighted imaging (SWI) is extremely sensitive in the detection of superparamagnetic iron oxide (SPIO) nanoparticle-labeled cells. However, no study has compared molecular imaging for stem cell detection using SWI and other MRI pulse sequences.

objectivesThis study aims to assess the sensitivity of SWI in detecting SPIO nanoparticle-labeled, human bone marrow-derived mesenchymal stem cells (SPIO-hMSCs) compared with that of T2- and T2*-weighted imaging (T2WI and T2*WI, respectively) in a phantom and in vivo study in rats. MATERIALS AND

methodsA phantom was prepared with various cell concentrations. In one normal rat, SPIO-hMSCs were implanted directly through burr holes into both caudate putamens, while in three rats without and six rats with photothrombotic infarction, 2.5 × 10(5)/ml SPIO-hMSCs were infused into the ipsilateral internal carotid artery (ICA). T2WI, T2*WI, and SWI findings were compared for dark regions representing SPIO-hMSCs.

resultsSWI and T2*WI detected 15 µL of 13 SPIO-hMSCs/µL and 15 µL of 27 SPIO-hMSCs/µL in the phantom, respectively and 3 µL of 333 SPIO-hMSCs/µL and 3 µL of 167 SPIO-hMSCs/µL in the normal rat brain (direct implantation). In the normal rat brain (ICA infusion), one of the three cases showed numerous foci of dark regions dispersed throughout the brain on T2*WI and SWI. Dark regions surrounded the infarcts in all six infracted rat brains. The dark region was most prominent on SWI, followed by T2*WI and T2WI in all six rats (P = 0.002). Implanted SPIO-hMSCs were confirmed using Prussian blue staining.

conclusionsSWI is the most sensitive in the detection of SPIO-hMSCs, with the dark regions representing SPIO-hMSCs being more prominent on SWI than on T2*WI and T2WI.

Indexed as

Cerebral InfarctionFerrosoferric OxideMesenchymal Stromal CellsRats

Identifiers

PMID25901258
PMCPMC4389178
OpenAlexW2063359646

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.