ArticleInternational journal of computer assisted radiology and surgery2015
Force adaptive robotically assisted endomicroscopy for intraoperative tumour identification.
Article in International journal of computer assisted radiology and surgery, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it, 24 citations in OpenAlex.
- Review of surgical robotic systems for keyhole and endoscopic procedures: state of the art and perspectives.Frontiers of medicine · 2020Pooled it
- A novel contact optimization algorithm for endomicroscopic surface scanning.International journal of computer assisted radiology and surgery · 2024Article
- Image computing for fibre-bundle endomicroscopy: A review.Medical image analysis · 2020Review
- Hybrid Robot-assisted Frameworks for Endomicroscopy Scanning in Retinal Surgeries.IEEE transactions on medical robotics and bionics · 2020Article
- A Novel Semi-Autonomous Control Framework for Retina Confocal Endomicroscopy Scanning.Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems · 2019Article
- A cable-driven parallel manipulator with force sensing capabilities for high-accuracy tissue endomicroscopy.International journal of computer assisted radiology and surgery · 2018Article
- Patent blue V and indocyanine green for fluorescence microimaging of human peritoneal carcinomatosis using probe-based confocal laser endomicroscopy.Surgical endoscopy · 2016Article
- Line-scanning fiber bundle endomicroscopy with a virtual detector slit.Biomedical optics express · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeFor effective tumour margin definition for cancer surgery, there is an increasing demand for the development of real-time intraoperative tissue biopsy techniques. Recent advances in miniaturized biophotonics probes have permitted the development of endomicroscopy techniques that are clinically attractive. With these approaches, cellular-level imaging can be achieved through millimetre-scale flexible probes and be performed in real-time, in vivo and in situ. Due to the limited field of view and flexibility of these probes, however, large area tissue coverage for acquiring histology-like images over complex three-dimensional surfaces is challenging. This is particularly the case because current surgical robots, such as the Da Vinci ®, lack haptic feedback, making it difficult to maintain optimum tissue contact when these probes are deployed in vivo.
methodsThis paper proposes a simple force-controlled pick-up probe that can be integrated with the Da Vinci instruments for intraoperative endomicroscopy imaging. The device uses a new low-friction air bearing with adaptive axial force control to maintain constant contact between the tissue and the imaging probe, facilitating microscopy scans over complex surfaces. Detailed ex vivo user experiments have been conducted to demonstrate the effectiveness of the technique.
resultsThe adaptive probe mount could achieve consistent low-magnitude probe-sample contact forces compared with a rigid mount. In the user study, the adaptive probe combined with a high frame rate endomicroscopy system allowed larger mosaics to be generated over curved surfaces.
conclusionsThe device can improve the performance of large area mosaicking over complex 3D surfaces with improved handling and intraoperative control.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.