Evidence map›Paper›PMID 25894766›Full record

ArticleJournal of occupational and environmental hygiene2015

Evaluation of Diesel Exhaust Continuous Monitors in Controlled Environmental Conditions.

Chang Ho Yu, Allison P Patton, Andrew Zhang, Zhi-Hua Tina Fan, Clifford P Weisel, Paul J Lioy

Abstract readEvaluation Study
In one paragraph

Article in Journal of occupational and environmental hygiene, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. A task-based analysis of black carbon exposure in Iowa farmers during harvest.Journal of occupational and environmental hygiene · 2018
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Chang Ho Yua Environmental and Occupational Health Sciences Institute, Rutgers University , Piscataway , New Jersey.
Allison P Patton
Andrew Zhang
Zhi-Hua Tina Fan
Clifford P Weisel
Paul J Lioy

Funding

Translational Research Support CoreP30ES005022 · NIEHS · UNIV OF MED/DENT NJ-R W JOHNSON MED SCH · PI Emily S Barrett · 1988 to 2026
$47.4M
Training Grant for the Joint Graduate Program in Exposure Science.T32ES019854 · NIEHS · UNIV OF MED/DENT NJ-R W JOHNSON MED SCH · PI MAINELIS, GEDIMINAS, WEISEL, CLIFFORD P · 2011 to 2020
$2.6M
NIEHS NIH HHS 1T32ES019854-01NIEHS NIH HHS P30 ES005022NIEHS NIH HHS P30ES005022NIEHS NIH HHS T32 ES019854
6 · The paper itself

Abstract

Diesel exhaust (DE) contains a variety of toxic air pollutants, including diesel particulate matter (DPM) and gaseous contaminants (e.g., carbon monoxide (CO)). DPM is dominated by fine (PM2.5) and ultrafine particles (UFP), and can be representatively determined by its thermal-optical refractory as elemental carbon (EC) or light-absorbing characteristics as black carbon (BC). The currently accepted reference method for sampling and analysis of occupational exposure to DPM is the National Institute for Occupational Safety and Health (NIOSH) Method 5040. However, this method cannot provide in-situ short-term measurements of DPM. Thus, real-time monitors are gaining attention to better examine DE exposures in occupational settings. However, real-time monitors are subject to changing environmental conditions. Field measurements have reported interferences in optical sensors and subsequent real-time readings, under conditions of high humidity and abrupt temperature changes. To begin dealing with these issues, we completed a controlled study to evaluate five real-time monitors: Airtec real-time DPM/EC Monitor, TSI SidePak Personal Aerosol Monitor AM510 (PM2.5), TSI Condensation Particle Counter 3007, microAeth AE51 BC Aethalometer, and Langan T15n CO Measurer. Tests were conducted under different temperatures (55, 70, and 80°F), relative humidity (10, 40, and 80%), and DPM concentrations (50 and 200 μg/m(3)) in a controlled exposure facility. The 2-hr averaged EC measurements from the Airtec instrument showed relatively good agreement with NIOSH Method 5040 (R(2) = 0.84; slope = 1.17±0.06; N = 27) and reported ∼17% higher EC concentrations than the NIOSH reference method. Temperature, relative humidity, and DPM levels did not significantly affect relative differences in 2-hr averaged EC concentrations obtained by the Airtec instrument vs. the NIOSH method (p < 0.05). Multiple linear regression analyses, based on 1-min averaged data, suggested combined effects of up to 5% from relative humidity and temperature on real-time measurements. The overall deviations of these real-time monitors from the NIOSH method results were ≤20%. However, simultaneous monitoring of temperature and relative humidity is recommended in field investigations to understand and correct for environmental impacts on real-time monitoring data.

Indexed as

Air Pollutants, OccupationalCarbon MonoxideEnvironmental MonitoringHumidityNational Institute for Occupational Safety and Health, U.S.Particle SizeParticulate MatterTemperatureUnited StatesVehicle EmissionsAir Pollutants, OccupationalCarbon MonoxideParticulate MatterVehicle Emissionsdiesel exhaustdiesel particle matterenvironmental conditionsreal-time monitor

Identifiers

PMID25894766
PMCPMC4536149

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.