ArticleEuropean radiology2015
Discrepant screening mammography assessments at blinded and non-blinded double reading: impact of arbitration by a third reader on screening outcome.
Article in European radiology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Retrospective evaluation of a CE-marked AI system, including 1,017,208 mammography screening examinations.European radiology · 2025Article
- Service and clinical impacts of reader bias in breast cancer screening: a retrospective study.The British journal of radiology · 2024Article
- Optimising breast cancer screening reading: blinding the second reader to the first reader's decisions.European radiology · 2022Observational
- Characteristics of screen-detected cancers following concordant or discordant recalls at blinded double reading in biennial digital screening mammography.European radiology · 2019Article
- Double versus single reading of mammograms in a breast cancer screening programme: a cost-consequence analysis.European radiology · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesTo determine the value of adding a third reader for arbitration of discrepant screening mammography assessments.
methodsWe included a consecutive series of 84,927 digital screening mammograms, double read in a blinded or non-blinded fashion. Arbitration was retrospectively performed by a third screening radiologist. Two years' follow-up was performed.
resultsDiscrepant readings comprised 57.2% (830/1452) and 29.1% (346/1188) of recalls at blinded and non-blinded double readings, respectively. At blinded double reading, arbitration would have decreased recall rate (3.4 to 2.2%, p < 0.001) and programme sensitivity (83.2 to 76.0%, p = 0.013), would not have influenced the cancer detection rate (CDR; 7.5 to 6.8 per 1,000 screens, p = 0.258) and would have increased the positive predictive value of recall (PPV; 22.3 to 31.2%, p < 0.001). At non-blinded double reading, arbitration would have decreased recall rate (2.8 to 2.3%, p < 0.001) and increased PPV (23.2 to 27.5%, p = 0.021), but would not have affected CDR (6.6 to 6.3 per 1,000 screens, p = 0.604) and programme sensitivity (76.0 to 72.7%, p = 0.308).
conclusionArbitration of discrepant screening mammography assessments is a good tool to improve recall rate and PPV, but is not desirable as it reduces the programme sensitivity at blinded double reading. KEY POINTS: • Blinded double reading results in higher programme sensitivity than non-blinded reading. • Discrepant readings occur more often at blinded compared to non-blinded reading. • Arbitration of discrepant readings reduces the recall rate and PPV. • Arbitration would reduce the programme sensitivity at blinded double reading.
Indexed as
Identifiers
25894007What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.