Evidence map›Paper›PMID 25893135›Full record

ArticleProceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems2014

Toward Automated Intraocular Laser Surgery Using a Handheld Micromanipulator.

Sungwook Yang, Robert A MacLachlan, Cameron N Riviere

Open access · greenAbstract read
In one paragraph

Article in Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
  3. Techniques for robot-aided intraocular surgery using monocular vision.The International journal of robotics research · 2018
    Article
  4. Article
  5. Comparative Evaluation of Handheld Robot-Aided Intraocular Laser Surgery.IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society · 2016
    Article
  6. Article
  7. Toward Monocular Camera-Guided Retinal Vein Cannulation with an Actively Stabilized Handheld Robot.IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Sungwook YangRobotics Institute, Carnegie Mellon University, Pittsburgh, PA 15213 USA.
Robert A MacLachlanRobotics Institute, Carnegie Mellon University, Pittsburgh, PA 15213 USA.
Cameron N RiviereRobotics Institute, Carnegie Mellon University, Pittsburgh, PA 15213 USA.
Carnegie Mellon University · US

Funding

A Microsurgical Assistant SystemR01EB007969 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI TAYLOR, RUSSELL H · 2008 to 2012
$5.7M
An Active Handheld MicromanipulatorR01EB000526 · NIBIB · CARNEGIE-MELLON UNIVERSITY · PI RIVIERE, CAMERON N · 2003 to 2017
$2.6M
NIBIB NIH HHS R01 EB000526NIBIB NIH HHS R01 EB007969
6 · The paper itself

Abstract

This paper presents a technique for automated intraocular laser surgery using a handheld micromanipulator known as Micron. The novel handheld manipulator enables the automated scanning of a laser probe within a cylinder of 4 mm long and 4 mm in diameter. For the automation, the surface of the retina is reconstructed using a stereomicroscope, and then preplanned targets are placed on the surface. The laser probe is precisely located on the target via visual servoing of the aiming beam, while maintaining a specific distance above the surface. In addition, the system is capable of tracking the surface of the eye in order to compensate for any eye movement introduced during the operation. We compared the performance of the automated scanning using various control thresholds, in order to find the most effective threshold in terms of accuracy and speed. Given the selected threshold, we conducted the handheld operation above a fixed target surface. The average error and execution time are reduced by 63.6% and 28.5%, respectively, compared to the unaided trials. Finally, the automated laser photocoagulation was demonstrated also in an eye phantom, including compensation for the eye movement.

Identifiers

PMID25893135
PMCPMC4398397
OpenAlexW2085223559

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.