Evidence map›Paper›PMID 25889863›Full record

ArticleJournal of nanobiotechnology2015

Dual-imaging model of SQUID biosusceptometry for locating tumors targeted using magnetic nanoparticles.

Jen-Jie Chieh, Kai-Wen Huang, Yi-Yan Lee, Wen-Chun Wei

Open access · goldAbstract read
In one paragraph

Article in Journal of nanobiotechnology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 19 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Jen-Jie ChiehInstitute of Electro-Optical Science and Technology, National Taiwan Normal University, Taipei, 116, Taiwan. jjchieh@ntnu.edu.tw.
Kai-Wen HuangDepartment of Surgery and Hepatitis Research Center, National Taiwan University Hospital, Taipei, 100, Taiwan. skywing@ntuh.gov.tw.
Yi-Yan LeeInstitute of Electro-Optical Science and Technology, National Taiwan Normal University, Taipei, 116, Taiwan. ricky337218@hotmail.com.
Wen-Chun WeiInstitute of Electro-Optical Science and Technology, National Taiwan Normal University, Taipei, 116, Taiwan. litwen_6622@yahoo.com.tw.
National Taiwan Normal University · TWNational Taiwan University Hospital · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFor intraoperative imaging in operating theaters or preoperative imaging in clinics, compact and economic integration rather than large and expensive equipment is required to coregister structural and functional imaging. However, current technologies, such as those integrating optical and gamma cameras or infrared and fluorescence imaging, involve certain drawbacks, including the radioactive biorisks of nuclear medicine indicators and the inconvenience of conducting measurements in dark environments.

methodsTo specifically and magnetically label liver tumors, an anti-alpha-fetoprotein (AFP) reagent was synthesized from biosafe iron oxide magnetic nanoparticles (MNPs) coated with anti-AFP antibody and solved in a phosphate buffered saline solution. In addition, a novel dual-imaging model system integrating an optical camera and magnetic scanning superconducting-quantum-interference device (SQUID) biosusceptometry (SSB) was proposed. The simultaneous coregistration of low-field magnetic images of MNP distributions and optical images of anatomical regions enabled the tumor distribution to be determined easily and in real time. To simulate targeted MNPs within animals, fewer reagents than the injected dose were contained in a microtube as a sample for the phantom test. The phantom test was conducted to examine the system characteristics and the analysis method of dual images. Furthermore, the animal tests were classified into two types, with liver tumors implanted either on the backs or livers of rats. The tumors on the backs were to visually confirm the imaging results of the phantom test, and the tumors on the livers were to simulate real cases in hepatocellular carcinoma people.

resultsA phantom test was conducted using the proposed analysis method; favorable contour agreement was shown between the MNP distribution in optical and magnetic images. Consequently, the positioning and discrimination of liver tumors implanted on the backs and livers of rats were verified by conducting in vivo and ex vivo tests. The results of tissue staining verified the feasibility of using this method to determine the distribution of liver tumors.

conclusionThe results of this study indicate the clinical potential of using anti-AFP-mediated MNPs and the dual-imaging model SSB for discriminating and locating tumors.

Indexed as

Magnetite Nanoparticlesalpha-FetoproteinsAnimalsEquipment DesignImage Processing, Computer-AssistedIntraoperative CareLiver Neoplasms, ExperimentalMagnetometryMalePhantoms, ImagingPreoperative CareRatsRats, Inbred F344Video Recordingalpha-FetoproteinsMagnetite Nanoparticles

Identifiers

PMID25889863
PMCPMC4329206
OpenAlexW2136827471

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.