Evidence map›Paper›PMID 25889833›Full record

ArticleVirology journal2015

Recombinant adenovirus as a model to evaluate the efficiency of free chlorine disinfection in filtered water samples.

Mariana A Nascimento, Maria E Magri, Camila D Schissi, Célia Rm Barardi

Open access · goldAbstract readEvaluation Study
In one paragraph

Article in Virology journal, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Human and animal enteric virus in groundwater from deep wells, and recreational and network water.Environmental science and pollution research international · 2015
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Mariana A NascimentoLaboratório de Virologia Aplicada, Departamento de Microbiologia, Imunologia e Parasitologia, Universidade Federal de Santa Catarina, 88040-900, Florianópolis, Santa Catarina, Brazil. mari_aln@hotmail.com.
Maria E MagriLaboratório de Virologia Aplicada, Departamento de Microbiologia, Imunologia e Parasitologia, Universidade Federal de Santa Catarina, 88040-900, Florianópolis, Santa Catarina, Brazil. mariaelisamagri@yahoo.com.br.
Camila D SchissiLaboratório de Virologia Aplicada, Departamento de Microbiologia, Imunologia e Parasitologia, Universidade Federal de Santa Catarina, 88040-900, Florianópolis, Santa Catarina, Brazil. camilaschissi@gmail.com.
Célia Rm BarardiLaboratório de Virologia Aplicada, Departamento de Microbiologia, Imunologia e Parasitologia, Universidade Federal de Santa Catarina, 88040-900, Florianópolis, Santa Catarina, Brazil. celia.barardi@ufsc.br.
Universidade Federal de Santa Catarina · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn Brazil, ordinance no. 2,914/2011 of the Ministry of Health requires the absence of total coliforms and Escherichia coli (E. coli) in treated water. However it is essential that water treatment is effective against all pathogens. Disinfection in Water Treatment Plants (WTP) is commonly performed with chlorine.

methodsThe recombinant adenovirus (rAdV), which expresses green fluorescent protein (GFP) when cultivated in HEK 293A cells, was chosen as a model to evaluate the efficiency of chlorine for human adenovirus (HAdV) inactivation in filtered water samples from two WTPs: Lagoa do Peri (pH 6.9) and Morro dos Quadros (pH 6.5). Buffered demand free (BDF) water (pH 6.9 and 8.0) was used as control. The samples were previously submitted to physicochemical characterization, and bacteriological analysis. Two free chlorine concentrations and two temperatures were assayed for all samples (0.2 mg/L, 0.5 mg/L, and 15°C, and 20°C). Fluorescence microscopy (FM) was used to check viral infectivity in vitro and qPCR as a molecular method to determine viral genome copies. Real treated water samples from the WTP (at the output of WTP and the distribution network) were also evaluated for total coliforms, E. coli and HAdV.

resultsThe time required to inactivate 4log₁₀ of rAdV was less than 1 min, when analyzed by FM, except for BDF pH 8.0 (up to 2.5 min for 4log₁₀). The pH had a significant influence on the efficiency of disinfection. The qPCR assay was not able to provide information regarding rAdV inactivation. The data were modeled (Chick-Watson), and the observed Ct values were comparable with the values reported in the literature and smaller than the values recommended by the EPA. In the treated water samples, HAdV was detected in the distribution network of the WTP Morro dos Quadros (2.75 × 10(3) PFU/L).

conclusionThe Chick-Watson model proved to have adjusted well to the experimental conditions used, and it was possible to prove that the adenoviruses were rapidly inactivated in the surface water treated with chlorine and that the recombinant adenovirus expressing GFP is a good model for this evaluation.

Indexed as

Adenoviruses, HumanBrazilChlorineDisinfectantsDisinfectionFiltrationFresh WaterHumansVirus InactivationWater PurificationChlorineDisinfectants

Identifiers

PMID25889833
PMCPMC4349469
OpenAlexW2115753520

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.