Evidence map›Paper›PMID 25887163›Full record

ReviewBMC surgery2015

Endovascular repair of abdominal aortic aneurysm with severely angulated neck and tortuous artery access: case report and literature review.

Qinglong Zeng, Lianjun Huang, Xiaoyong Huang, Mingliang Peng

Open access · goldAbstract readCase ReportsReview
In one paragraph

Review in BMC surgery, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.7field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 16 citations in OpenAlex.

  1. A simple and fast technique to cannulate the contralateral gate.Journal of vascular surgery cases and innovative techniques · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Qinglong ZengAortic Center of Anzhen Hospital affiliated to Capital Medical University, Beijing, China.
Lianjun HuangAortic Center of Anzhen Hospital affiliated to Capital Medical University, Beijing, China. huanglianjun2008@163.com.
Xiaoyong HuangAortic Center of Anzhen Hospital affiliated to Capital Medical University, Beijing, China.
Mingliang PengAortic Center of Anzhen Hospital affiliated to Capital Medical University, Beijing, China.
Capital Medical University · CNBeijing Anzhen Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundEndovascular aneurysm repair has revolutionized the therapeutic strategy for abdominal aortic aneurysm. However, hostile proximal aneurysmal neck and tortuosity of access vessels remain challenges in selecting optimal stent-grafts in abdominal aortic aneurysms with difficult anatomy. CASE PRESENTATION: A 65-year-old woman complained of intermittent abdominal pain for one week. Computed tomography angiogram demonstrated a tortuous infrarenal abdominal aortic aneurysm with a tapered neck and a 136° of infrarenal angulation. Aneurysmal dilatation and severe calcification of bilateral iliac arteries and tortuous aortoiliac access were also showed. Endovascular approach using Endurant stent-graft was attempted at an outside hospital, but failed because of the significant tortuosity of the abdominal aorta and iliac arteries. Since the patient refused to have open aneurysm repair, he was transferred to our hospital for further evaluation and possible EVAR with a different approach. EVAR was performed successfully using Gore Excluder stent-grafts (W.L. Gore & Associates, Flagstaff, AZ, USA). During the procedure, cannulation of the contralateral limb was unable to be achieved because of the tortuous aortoiliac course. Therefore, a snare was inserted from right radial artery, through the contralateral gate, to grasp the wire from left femoral artery. Two iliac stent-grafts were sequentially deployed with the lower end distal to the opening of the left internal iliac artery. Angiography confirmed complete sealing of the aneurysm with patency of bilateral renal arteries and external iliac arteries. The postoperative courses were uneventful and follow-up computed tomography angiogram at 6 months demonstrated patent bilateral femoral and renal arteries without endoleaks or stent migration.

conclusionAlthough endovascular repair of aortic aneurysm with hostile neck and tortuous access is rather challenging, choosing flexible stent-grafts and suitable techniques is able to achieve an encouraging outcome.

Indexed as

AgedAortic Aneurysm, AbdominalBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationEndovascular ProceduresFemaleHumansStents

Identifiers

PMID25887163
PMCPMC4357166
OpenAlexW2033637143

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.