Evidence map›Paper›PMID 25880286›Full record

ArticleJournal of cardiothoracic surgery2015

Failing stentless Bioprostheses in patients with carcinoid heart valve disease.

Andreas Schaefer, Bjoern Sill, Jeannette Schoenebeck, Yvonne Schneeberger, Hermann Reichenspurner, Helmut Gulbins

Open access · goldAbstract readCase Reports
In one paragraph

Article in Journal of cardiothoracic surgery, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.1field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 7 citations in OpenAlex.

  1. Review
  2. Article
  3. Valvular Disorders in Carcinoid Heart Disease.Brazilian journal of cardiovascular surgery
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Andreas SchaeferDepartment of Cardiovascular Surgery, University Heart Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany. and.schaefer@uke.de.
Bjoern SillDepartment of Cardiovascular Surgery, University Heart Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany. sill@uke.de.
Jeannette SchoenebeckDepartment of Cardiovascular Surgery, University Heart Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany. j.schoenebeck@uke.de.
Yvonne SchneebergerDepartment of Cardiovascular Surgery, University Heart Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany. y.schneeberger@uke.de.
Hermann ReichenspurnerDepartment of Cardiovascular Surgery, University Heart Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany. reichenspurner@uke.de.
Helmut GulbinsDepartment of Cardiovascular Surgery, University Heart Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany. h.gulbins@uke.de.
University Medical Center Hamburg-Eppendorf · DEUniversität Hamburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCarcinoid tumor with consecutive endocardial fibroelastosis of the right heart, known as carcinoid heart valve disease (CHVD) or Hedinger's syndrome, is accompanied by combined right-sided valvular dysfunction with regurgitation and stenosis of the affected valves. Cardiac surgery with replacement of the tricuspid and/or pulmonary valve is an established therapeutic option for patients with Hedinger's syndrome. Little is known about the long term outcome and the choice of prosthesis for the pulmonal position is still a matter of debate.

methodsThe authors report three cases of pulmonary valve replacement with stentless bioprostheses (Medtronic Freestyle, Medtronic PLC, Minneapolis, MN, USA) due to severe pulmonary valve degeneration in consequence of Hedinger's syndrome.

resultsAll patients presented with re-stenosis of the pulmonal valve conduit at the height of the anastomoses in a premature fashion. Due to the increased risk for repeat surgical valve replacement, two patients were treated by transcatheter heart valves.

conclusionWe do not recommend the replacement of the pulmonary valve with stentless bioprostheses in patients with CHVD. These valves presented with an extreme premature degeneration and consecutive re-stenosis and heart failure.

Indexed as

BioprosthesisHeart Valve ProsthesisAdultCarcinoid Heart DiseaseFemaleHeart Valve Prosthesis ImplantationHumansMaleMiddle AgedPulmonary Valve InsufficiencyPulmonary Valve StenosisRecurrenceReoperation

Identifiers

PMID25880286
PMCPMC4377042
OpenAlexW2117579612

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.