ArticleInternational journal of analytical chemistry2015
Extraction of HCV-RNA from Plasma Samples: Development towards Semiautomation.
Article in International journal of analytical chemistry, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 5 citations in OpenAlex.
- Comprehensive Review on Viral RNA Extraction Strategies for Enhanced Molecular Diagnostics.Interdisciplinary perspectives on infectious diseases · 2025Review
- Corrigendum to "Extraction of HCV-RNA from Plasma Samples: Development towards Semiautomation".International journal of analytical chemistry · 2016Article
Corrections and comments
- Erratum issued
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A semiautomated extraction protocol of HCV-RNA using Favorgen RNA extraction kit has been developed. The kit provided protocol was modified by replacing manual spin steps with vacuum filtration. The assay performance was evaluated by real-time qPCR based on Taqman technology. Assay linearity was confirmed with the serial dilutions of RTA (Turkey) containing 1 × (10(6), 10(5), 10(4), and 10(3)) IU mL(-1). Comparison of test results obtained by two extraction methods showed a good correlation (r = 0.95, n = 30) with detection limit of 10(2) IU mL(-1). The semiautomated vacuum filtration based protocol demonstrated high throughput: 35 minutes for the extraction of a batch of 30 samples (150 µL each) with reduced labor, time, waste, and cost. Performance characteristics of semiautomated system make it suitable for use in diagnostic purpose and viral load determinations.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.