Analytical Performance Requirements for Systems for Self-Monitoring of Blood Glucose With Focus on System Accuracy: Relevant Differences Among ISO 15197:2003, ISO 15197:2013, and Current FDA Recommendations.

Guido Freckmann, Christina Schmid, Annette Baumstark, Malte Rutschmann, Cornelia Haug, Lutz Heinemann

Abstract readReview
In one paragraph

Review in Journal of diabetes science and technology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update.Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists · 2022
    Guideline
  2. Pooled it
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Review
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Guido FreckmannInstitut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH, Ulm, Germany guido.freckmann@uni-ulm.de.
Christina SchmidInstitut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH, Ulm, Germany.
Annette BaumstarkInstitut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH, Ulm, Germany.
Malte RutschmannEdingen-Neckarhausen, Germany.
Cornelia HaugInstitut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH, Ulm, Germany.
Lutz HeinemannProfil Institut für Stoffwechselforschung GmbH, Neuss, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In the European Union (EU), the ISO (International Organization for Standardization) 15197 standard is applicable for the evaluation of systems for self-monitoring of blood glucose (SMBG) before the market approval. In 2013, a revised version of this standard was published. Relevant revisions in the analytical performance requirements are the inclusion of the evaluation of influence quantities, for example, hematocrit, and some changes in the testing procedures for measurement precision and system accuracy evaluation, for example, number of test strip lots. Regarding system accuracy evaluation, the most important change is the inclusion of more stringent accuracy criteria. In 2014, the Food and Drug Administration (FDA) in the United States published their own guidance document for the premarket evaluation of SMBG systems with even more stringent system accuracy criteria than stipulated by ISO 15197:2013. The establishment of strict accuracy criteria applicable for the premarket evaluation is a possible approach to further improve the measurement quality of SMBG systems. However, the system accuracy testing procedure is quite complex, and some critical aspects, for example, systematic measurement difference between the reference measurement procedure and a higher-order procedure, may potentially limit the apparent accuracy of a given system. Therefore, the implementation of a harmonized reference measurement procedure for which traceability to standards of higher order is verified through an unbroken, documented chain of calibrations is desirable. In addition, the establishment of regular and standardized post-marketing evaluations of distributed test strip lots should be considered as an approach toward an improved measurement quality of available SMBG systems.

Indexed as

Blood GlucoseBlood Glucose Self-MonitoringDiabetes MellitusEuropeGuidelines as TopicHematocritHumansHypoglycemiaReproducibility of ResultsUnited StatesUnited States Food and Drug AdministrationBlood Glucoseblood glucose monitoringFDA draft guidance documentISO 15197:2003ISO 15197:2013SMBG systemssystem accuracy

Identifiers

PMID25872965
PMCPMC4525642

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.