Evidence map›Paper›PMID 25872487›Full record

ArticleLasers in surgery and medicine2015

Comparing high-resolution microscopy techniques for potential intraoperative use in guiding low-grade glioma resections.

Daphne Meza, Danni Wang, Yu Wang, Sabine Borwege, Nader Sanai, Jonathan T C Liu

Abstract readComparative Study
In one paragraph

Article in Lasers in surgery and medicine, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Dual-axis confocal microscopy for point-of-care pathology.IEEE journal of selected topics in quantum electronics : a publication of the IEEE Lasers and Electro-optics Society
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Daphne MezaDepartment of Biomedical Engineering, Stony Brook University (SUNY), Stony Brook, New York, 11794.
Danni Wang
Yu Wang
Sabine Borwege
Nader Sanai
Jonathan T C Liu
Stony Brook University · USUniversity of Washington · USBarrow Neurological Institute · USSt. Joseph Hospital · US

Funding

Line-scanned MEMS-based dual-axis confocal microscopy to detect oral lesions in vR01DE023497 · NIDCR · UNIVERSITY OF WASHINGTON · PI LIU, JONATHAN T.C. · 2012 to 2014
$2.4M
Molecular Mechanisms Underlying Glioma Invasion of the Human Subventricular ZoneR01NS082745 · NINDS · ST. JOSEPH'S HOSPITAL AND MEDICAL CENTER · PI SANAI, NADER · 2013 to 2017
$1.8M
Intraoperative confocal microscopy for quantitative delineation of low-grade glioR01CA175391 · NCI · UNIVERSITY OF WASHINGTON · PI LIU, JONATHAN T.C., SANAI, NADER · 2014 to 2018
$1.7M
Dual-axis Confocal Microscope for Image-guided Resection of MedulloblastomaR00EB008557 · NIBIB · STATE UNIVERSITY NEW YORK STONY BROOK · PI LIU, JONATHAN T.C. · 2010 to 2012
$724k
NCI NIH HHS R01 CA175391NIBIB NIH HHS R00 EB008557NIDCR NIH HHS R01 DE023497NINDS NIH HHS R01 NS082745
6 · The paper itself

Abstract

BACKGROUND AND

objectivesFluorescence image-guided surgery (FIGS), with contrast provided by 5-ALA-induced PpIX, has been shown to enable a higher extent of resection of high-grade gliomas. However, conventional FIGS with low-power microscopy lacks the sensitivity to aid in low-grade glioma (LGG) resection because PpIX signal is weak and sparse in such tissues. Intraoperative high-resolution microscopy of PpIX fluorescence has been proposed as a method to guide LGG resection, where sub-cellular resolution allows for the visualization of sparse and punctate mitochondrial PpIX production in tumor cells. Here, we assess the performance of three potentially portable high-resolution microscopy techniques that may be used for the intraoperative imaging of human LGG tissue samples with PpIX contrast: high-resolution fiber-optic microscopy (HRFM), high-resolution wide-field microscopy (WFM), and dual-axis confocal (DAC) microscopy. MATERIALS AND

methodsThick unsectioned human LGG tissue samples (n = 7) with 5-ALA-induced PpIX contrast were imaged using three imaging techniques (HRFM, WFM, DAC). The average signal-to-background ratio (SBR) was then calculated for each imaging modality (5 images per tissue, per modality).

resultsHRFM provides the ease of use and portability of a flexible fiber bundle, and is simple and inexpensive to build. However, in most cases (6/7), HRFM is not capable of detecting PpIX signal from LGGs due to high autofluorescence, generated by the fiber bundle under laser illumination at 405 nm, which overwhelms the PpIX signal and impedes its visualization. WFM is a camera-based method possessing high lateral resolution but poor axial resolution, resulting in sub-optimal image contrast.

conclusionsConsistent successful detection of PpIX signal throughout our human LGG tissue samples (n = 7), with an acceptable image contrast (SBR >2), was only achieved using DAC microscopy, which offers superior image resolution and contrast that is comparable to histology, but requires a laser-scanning mechanism to achieve optical sectioning.

Indexed as

Aminolevulinic AcidBrain NeoplasmsGliomaHumansIntraoperative CareMicroscopyNeuronavigationNeurosurgical ProceduresPhotosensitizing AgentsAminolevulinic AcidPhotosensitizing Agents5-ALAendomicroscopyextent of resectiongliomaintraoperative high-resolution microscopymicroendoscopyneurosurgeryPpIX

Identifiers

PMID25872487
PMCPMC4500631
OpenAlexW1923944168

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.